Laryngeal Radiation Fibrosis: A Case of Failed Awake Flexible Fibreoptic Intubation

نویسندگان

  • Johannes M. Huitink
  • Lambert Zijp
چکیده

Awake fibreoptic intubation is accepted as the gold standard for intubation of patients with an anticipated difficult airway. Radiation fibrosis may cause difficulties during the intubation procedure. We present an unusual severe case of radiation induced changes to the larynx, with limited clinical symptoms, that caused failure of the fibreoptic intubation technique. A review of the known literature on radiation fibrosis and airway management is presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pentax-AWS videolaryngoscope for awake nasal intubation in patients with unstable necks.

In patients with unstable necks and at risk of pulmonary aspiration, awake fibreoptic intubation is often appropriate. However, stabilization of the neck can make fibreoptic intubation more difficult. I report the use of awake nasal intubation using the Pentax-Aiway Scope (AWS) in three patients with restricted neck movement, in whom awake fibreoptic intubation had failed. Case 1: a 59-yr-old m...

متن کامل

The intubating laryngeal mask airway in failed fibreoptic intubation.

PURPOSE Prediction of difficult tracheal intubation is not always reliable and management with fibreoptic intubation is not always successful. We describe two cases in which blind intubation through the intubating laryngeal mask airway (ILMA FasTrach) succeeded after fibreoptic intubation failed. CLINICAL FEATURES The first patient, a 50 yr old man, was scheduled for elective craniotomy for i...

متن کامل

Correction to: Local block and Awake Intubation in a Patient with Laryngeal Mass and Anticipated Difficult Airway: A Case Report

Correction to: Local block and Awake Intubation in a Patient with Laryngeal Mass and Anticipated Difficult Airway: A Case Report       Hooshang Akbari1, Ravanbakhsh Esmaeili2   1 Assistant Professor, Department of Anesthesiology, Faculty of Paramedical, Mazandaran University of Medical Sciences, Sari, Iran 2 Assistant Professor, Department of Medical Surgical Nursing...

متن کامل

Fibreoptic intubation--a case series and brief review.

Fibreoptic intubation has been established as a major advance in the management of difficult or failed intubation in the awake patient. If necessary, it may be performed under general anaesthesia with either spontaneous or controlled ventilation. This should be considered early in the management of failed intubation, before multiple attempts with other techniques lead to haemorrhage and oedema ...

متن کامل

Cannot ventilate, difficult to intubate.

EDITOR: We read with interest the letter by Slater and Bhatia [1] and would like to congratulate them on their successful management. We agree that the safest approach for their patient would have been an awake fibreoptic intubation. However, we would like to make a few comments. From the history and picture, it is not clear whether the patient had a prosthesis fitted into the left orbital cavi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -