Thermo-wrap technology preserves normothermia better than routine thermal care in patients undergoing off-pump coronary artery bypass and is associated with lower immune response and lesser myocardial damage.
نویسندگان
چکیده
OBJECTIVE Perioperative hypothermia might be detrimental to the patient undergoing off-pump coronary artery bypass surgery. We assessed the efficacy of the Allon thermoregulation system (MTRE Advanced Technologies Ltd, Or-Akiva, Israel) compared with that of routine thermal care in maintaining normothermia during and after off-pump coronary artery bypass surgery. METHODS Patients undergoing off-pump coronary artery bypass surgery were perioperatively and randomly warmed with the 2 techniques (n = 45 per group). Core temperature, hemodynamics, and troponin I, interleukin 6, interleukin 8, and interleukin 10 blood levels were assessed. RESULTS The mean temperature of the patients in the Allon thermoregulation system group (AT group) was significantly ( P < .005) higher than that of the patients receiving routine thermal care (the RTC group); less than 40% of the latter reached 36 degrees C compared with 100% of the former. The cardiac index was higher and the systemic vascular resistance was lower ( P < .05) by 16% and 25%, respectively, in the individuals in the AT group compared with in the individuals in the RTC group during the 4 postoperative hours. End-of-surgery interleukin 6 levels and 24-hour postoperative troponin I levels were significantly ( P < .01) lower in the patients in the AT group than in the RTC group. The RTC group's troponin levels closely correlated with their interleukin 6 levels at the end of the operation ( R = 0.51, P = .002). CONCLUSIONS Unlike routine thermal care, the Allon thermoregulation system maintains core normothermia in more than 80% of patients undergoing off-pump coronary artery bypass surgery. Normothermia is associated with better cardiac and vascular conditions, a lower cardiac injury rate, and a lower inflammatory response. The close correlation between the increased interleukin 6 and troponin I levels in the routine thermal care group indicates a potential deleterious effect of lowered temperature on the patient's outcome.
منابع مشابه
Cardiopulmonary Support and Physiology Thermo-wrap technology preserves normothermia better than routine thermal care in patients undergoing off-pump coronary artery bypass and is associated with lower immune response and lesser myocardial damage
Results: The mean temperature of the patients in the Allon thermoregulation system group (AT group) was significantly (P .005) higher than that of the patients receiving routine thermal care (the RTC group); less than 40% of the latter reached 36°C compared with 100% of the former. The cardiac index was higher and the systemic vascular resistance was lower (P .05) by 16% and 25%, respectively, ...
متن کاملمقایسهی نتایج استفاده از شانت داخل عروق کرونر در عمل بایپس عروق کرونر بدون پمپ نسبت به عدم استفاده از آن
Background and Objective: Off pump coronary artery bypass graft can be done with or without using intracoronary shunt. We have compared these two methods in early postoperative period, in this study. Materials and Methods: 208 candidate patients for off pump coronary artery bypass graft were devided in to two groups randomly for using intracoronary shunt or not. Variables including peri and pos...
متن کاملUse of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملComparison of Treatment Outcomes in Off-pump Coronary Artery Bypass Graft and Medical Therapy in Patients with Triple-vessel Coronary Artery Disease and Severe Ventricular Dysfunction
Introduction: Heart failure is a major hazard for public health. Despite recent advance in medical therapy, there is not enough information on the outcome of off-pump coronary artery bypass (OPCAB) and medical therapy on the patients with severe ventricular dysfunction and triple-vessel (CAD). This study aimed to compare treatment outcomes and mortality rate in patients undergoing off-pump coro...
متن کاملجراحی بای پس عروق کرونر بدون استفاده از ماشین قلب- ریه: روشی مطمئن برای ریواسکولاریزیشن کامل
In recent years off-pump coronary artery bypass surgery (OPCAB) has emerged as preferred method for revascularization of coronary arteries in relatively selected group of patients. Considering patients receiving incomplete revascularization need significantly higher postoperative catheterization and re-intervention (PTCA or CABG), we performed this study to identify safety and feasibility of th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 129 6 شماره
صفحات -
تاریخ انتشار 2005