Fabrication of a silver particle-integrated silicone polymer-covered metal stent against sludge and biofilm formation and stent-induced tissue inflammation
نویسندگان
چکیده
To reduce tissue or tumor ingrowth, covered self-expandable metal stents (SEMSs) have been developed. The effectiveness of covered SEMSs may be attenuated by sludge or stone formation or by stent clogging due to the formation of biofilm on the covering membrane. In this study, we tested the hypothesis that a silicone membrane containing silver particles (Ag-P) would prevent sludge and biofilm formation on the covered SEMS. In vitro, the Ag-P-integrated silicone polymer-covered membrane exhibited sustained antibacterial activity, and there was no definite release of silver ions from the Ag-P-integrated silicone polymer membrane at any time point. Using a porcine stent model, in vivo analysis demonstrated that the Ag-P-integrated silicone polymer-covered SEMS reduced the thickness of the biofilm and the quantity of sludge formed, compared with a conventional silicone-covered SEMS. In vivo, the release of silver ions from an Ag-P-integrated silicone polymer-covered SEMS was not detected in porcine serum. The Ag-P-integrated silicone polymer-covered SEMS also resulted in significantly less stent-related bile duct and subepithelium tissue inflammation than a conventional silicone polymer-covered SEMS. Therefore, the Ag-P-integrated silicone polymer-covered SEMS reduced sludge and biofilm formation and stent-induced pathological changes in tissue. This novel SEMS may prolong the stent patency in clinical application.
منابع مشابه
Application of a silver coating on plastic biliary stents to prevent biofilm formation: an experimental study using electron microscopy
Background and study aims: Biliary stent dysfunction is mainly caused by biliary sludge that forms as a result of bacterial adherence and subsequent biofilm formation on the inner surface of the stent. Silver ions arewell known to have excellent antimicrobial activity against a wide range of microorganisms. In this study, we designed and constructed silver-coated plastic stent (PS) and investig...
متن کاملFabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel
Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...
متن کاملSubclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis
Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...
متن کاملRecurrent airway obstructions in a patient with benign tracheal stenosis and a silicone airway stent: a case report
Airway stents (silicone and metal stents) are used to treat patients with benign tracheal stenosis, who are symptomatic and in whom tracheal surgical reconstruction has failed or is not appropriate. However airway stents are often associated with complications such as migration, granuloma formation and mucous hypersecretion, which cause significant morbidity, especially in patients with benign ...
متن کاملNd-YAG laser damage to metal and silicone endobronchial stents: delineation of margins of safety using an in vitro experimental model.
STUDY OBJECTIVE To identify margins of safety within which bronchoscopic Nd-YAG laser resection can be performed without damaging indwelling tracheobronchial stents. DESIGN Experimental in vitro study simulating a patient-care environment. METHODS Uncovered and covered metal Wallstent (Schneider; Zurich, Switzerland) and Dumon (Bryan Corporation; Woburn, MA) silicone stents were deployed in...
متن کامل