Imaging of Scaphoid Fractures According to the New S3 Guidelines.

نویسندگان

  • R Schmitt
  • H Rosenthal
چکیده

Up to 30 % of acute scaphoid fractures are missed in conventional radiography. CT and MRI should be early performed in the diagnostic workflow, when radiograms (dorsopalmar, lateral and Stecher's views) are negative or inconclusive in fracture detection. Significance of CT is different from that of MRI: Sensitivity of CT imaging (85 to 95 %) is superior to conventional radiography (about 70 %), but inferior to MRI (almost 100 %). However, CT (specificity 95 to 100 %) is able to provide more detailed anatomic information of the fracture pattern when compared to MRI (specificity 80 to 90 %). Particularly, differentiation of bone contusion ("bone bruise") and non-displaced fracture can be difficult in MRI. Thus, CT indication is not only given for fracture detection, but also for assessing the morphology in scaphoid fractures (localization, fragment dislocation, comminuted zones) and the fragment instability, too. MRI should be limited to equivocal trauma cases presenting pain in the snuff box, but with inconclusive CT findings. In CT and MRI of scaphoid fractures, image display must be aligned along the longitudinal extension of the scaphoid, either by acquiring or reformatting oblique-sagittal and oblique-coronal planes. Key points • Radiography can be limited to the dorsopalmar, lateral and Stecher's views in scaphoid fractures.• In CT and MR imaging, the dedicated anatomy of the scaphoid has to be covered with oblique-sagittal and oblique-coronal images.• CT provides most detailed information of scaphoid fractures (localization, fragment dislocation and instability pattern). However, its capability in detecting non-displaced fractures is inferior to MRI.• All scaphoid fractures are seen in MRI. But differentiation of bone contusion (bone bruise) and a non-displaced fracture can be crucial.• This order is recommended in the diagnostic algorithm of scaphoid fractures: 1. radiography, 2. CT, and 3. MRI. Citation Format: • Schmitt R, Rosenthal H. Imaging of Scaphoid Fractures According to the New S3 Guidelines. Fortschr Röntgenstr 2016; 188: 459 - 469.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

Introducing a Clinical Practice Guideline Using Early CT in the Diagnosis of Scaphoid and Other Fractures

OBJECTIVE We developed and implemented clinical practice guideline (CPG) using computerized tomography (CT) as the initial imaging method in the emergency department management of scaphoid fractures. We hypothesized that this CPG would decrease unnecessary immobilization and lead to earlier return to work. METHODS This observational study evaluated implementation of our CPG, which incorporate...

متن کامل

Scaphoid Fractures: A Comparison of Two Surgical Methods for Internal Fixation Using Either Herbert Screws or Multiple Pins

Background and Aims: Scaphoid fractures are the most common fractures of the wrist. This study compared the outcomes of two surgical internal fixation techniques, using either Herbert screws (HS group) or multiple pins (MP group), in the treatment of scaphoid fractures. Methods: This cross-sectional study was performed on 41 patients (23 in HS and 18 in MP groups) with unilateral scaphoid fract...

متن کامل

Early computed tomography compared with bone scintigraphy in suspected scaphoid fractures.

PURPOSE This study examined whether multidetector computed tomography (CT) is superior to bone scintigraphy for diagnosis of an occult scaphoid fracture. METHODS AND MATERIALS In a study period of 22 months, 100 consecutive patients with a clinically suspected scaphoid fracture and no fracture on scaphoid radiographs, were evaluated with CT within 24 hours after injury and bone scintigraphy b...

متن کامل

Comparison of CT and MRI for diagnosis of suspected scaphoid fractures.

BACKGROUND There is no consensus on the optimum imaging method to use to confirm the diagnosis of true scaphoid fractures among patients with suspected scaphoid fractures. This study tested the null hypothesis that computed tomography (CT) and magnetic resonance imaging (MRI) have the same diagnostic performance characteristics for the diagnosis of scaphoid fractures. METHODS Thirty-four cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 188 5  شماره 

صفحات  -

تاریخ انتشار 2016