Presumptive screening of suspected semen stain in situ using cotton swabs and bromochloroindolyl phosphate to detect prostatic acid phosphatase activity.

نویسندگان

  • F S Baechtel
  • J Brown
  • L D Terrell
چکیده

A novel approach to the presumptive screening of questioned semen stains has been developed which enables the rapid identification of stains which are devoid of semen. Questioned semen stains can be swabbed with a moist cotton swab, and the prostatic acid phosphatase (SAP) activity transferred to the swab identified through assay with 5-bromo-4-chloro-3-indolyl phosphate (BCIP). Controlled laboratory studies revealed that the BCIP swab procedure was as sensitive as the semiquantitative SAP test currently employed in the FBI Laboratory for the presumptive screening of semen stains. A validation study of the BCIP swab procedure in parallel with the current procedure using 4305 case evidence stains indicated that the BCIP swab procedure was as effective as the current procedure in identifying those questioned stains which lack semen. The advantage of the BCIP swab procedure is that it can be performed on questioned stains in situ and thereby avoids the requirement of removing and extracting the stain before assay of SAP activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

P-10: Effects of Cadmium on Reproductive Enzymes of Blood and Reproductive Tissues in Adult Male Mice

Background: Heavy metals such as cadmium (Cd2+) are natural components of the Earth's crust which can not be degraded or destroyed. Industrial, mining and agricultural activities, particularly the excessive use of phosphate fertilizers, have led to high levels of cadmium contamination at many locations worldwide. Some toxic effects of cadmium are due to its inhibition of various enzyme sys...

متن کامل

Isolation and characterization of a semen-specific protein from human seminal plasma: a potential new marker for semen identification.

The identification of semen is of paramount importance in the investigation of rape and other crimes involving sexual assault. The most commonly used procedures for semen identification center on the detection of sperm o r the detection of prostatic acid phosphatase activity; methods involving the detection of spermine, choline, or semen antigens are less commonly employed. Unfortunately, none ...

متن کامل

Sensitivity of SERI’s AP Spot Test in the Detection of Acid Phosphatase

Acid phosphatase is an enzyme secreted by the prostate gland that is present in large amounts in seminal fluid. It, like psa (prostatic specific antigen), is not unique to the prostate and can be found in other biological fluids including vaginal secretions. It is therefore considered a presumptive chemical test for the presence of semen and semen must be confirmed by other means (sperm detecti...

متن کامل

The use of Polilight in the detection of seminal fluid, saliva, and bloodstains and comparison with conventional chemical-based screening tests. J Forensic Sci 2006;51(2):361-70.

Biological stains can be difficult to detect at crime scenes or on items recovered from crime scenes. The use of a versatile light source may assist in their detection. The ability of Polilight to locate potential semen, saliva, and blood stains on a range of substrates and at different dilutions was tested. We also tested the use of Polilight in comparison with conventional chemical-based pres...

متن کامل

Evaluation of Acid Phosphatase Activity Alterations in Mouse Endometrium After Ovarian Hyperstimulation During Early Natural and Pseudo Pregnancy Until Implantation Time

Purpose: The purpose of this study was to determine acid phosphatase (ACP) activity of uterus in natural and pseudo pregnanat mice after ovulation stimulation usmg PMSG and hCG during preimplantation period. Materials and Methods: In this experimental research, 6-10 week old female NMRI mice were selected and divided into two groups: control and hyperstimulated. These mice were rendered normal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of forensic sciences

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 1987