The biophysical effects of ultrasound on median nerve distal latencies.
نویسندگان
چکیده
PURPOSE Previous studies have documented the lack of ultrasound's non-thermal effects on nerve conduction using frequencies of 1 MHz and 870 kHz. The analyses and conclusions were reached, despite only one study incorporating pulsed ultrasound. The purpose of this study was to determine the biophysical effects of continuous wave (CW) and pulsed wave (PW) ultrasound on median nerve motor and sensory latencies using common frequencies of 1.0 and 3.0 MHz. SUBJECTS Fifteen healthy subjects (8 males, 7 females, age = 23.5 + 4.44 yrs, height = 171.2 + 10.7 cm, weight = 67.5 + 7.9 kg) without a history of neurological or musculoskeletal injury to their non-dominant arm volunteered for testing. METHODS AND MATERIALS Subjects were exposed in counterbalanced order to five ultrasound treatment conditions: (1) 1 MHz, 1.0 W/cm2, 8 min., (2) 1 MHz, 1.0 W/cm2, 50% PW, 8 min., (3) 3.0 MHz, 1.0 W/cm2, CW, 8 min., (4) 3.0 MHz, 1.0 W/cm2, 50% PW, 8 min., (5) placebo, 0.0 W/cm2, 8 min. Dependent measures for motor and sensory latencies, and subcutaneous temperatures were taken pretreatment, at 2, 4 and 6 minutes during treatment, and immediately post-treatment. Separate two within repeated measures ANOVA were used for each dependent measure. RESULTS Analysis revealed significant interactions for motor latencies [F (16,224) = 52.77, p < .001], sensory latencies [F (16,224) = 41.10, p < .001], and subcutaneous temperatures [F (16,224) = 52.77, p < .001]. Tukey's HSD post hoc analyses confirmed that nerve latencies responded similarly to subcutaneous temperature changes during and after ultrasound treatment. CONCLUSIONS Alterations in nerve latencies from ultrasound on healthy nerves appeared to be related to temperature changes induced by ultrasound's thermal effects, and not by non-thermal or mechanical effects.
منابع مشابه
میزان تغییر تأخیر زمانی شاخه حسی و حرکتی عصب میانی در مچ دست برحسب سن
Introduction: Even though there is a high prevalence of carpal tunnel syndrome patients, there are very few reliable papers on the study of normal values and changes in sensory and motor latency parameters of the median nerve in the wrist region on the basis of age of patients .This retrospective study was on the basis of 5 years data (1998 -2003) from the electro diagnostic department of Sh. S...
متن کاملیافته های طبیعی هدایت عصبی مدیان، مرکز الکترومیوگرافی بیمارستان سینا
Because of high prevalence of upper limbs pain and carpal tunnel sndrome and the need of proofing of diagnosis by nerve conduction study (NCS) testing of edian nerve is one of the most common exams in electro-diagnostic centers. In interpretation of findings of nerve conduction study presence of a normal range for findings is one of the most important points.Materials and Methods: In this study...
متن کاملThe Effect of Neuromobilization on Clinical Findings in Patients with Carpal Tunnel Syndrome
Objective: Neuromobilization techniques have been recently put forward in physiotherapy of carpal tunnel syndrome. The aim of this study was to assess the effect of neuromobilization on different aspects of evaluation including subjective, physical, and electrophysiological findings in CTS. Materials & Methods: In this randomized clinical trial study, 20 patients with carpal tunnel syndrome ...
متن کاملPulsed magnetic field versus ultrasound in the treatment of postnatal carpal tunnel syndrome: A randomized controlled trial in the women of an Egyptian population
The aim of this study was to compare the effects of pulsed electromagnetic field versus pulsed ultrasound in treating patients with postnatal carpal tunnel syndrome. The study was a randomized, double-blinded trial. Forty postnatal female patients with idiopathic carpal tunnel syndrome were divided randomly into two equal groups. One group received pulsed electromagnetic field, with nerve and t...
متن کاملAcute Combined Median and Radial Nerve Palsies after Distal Humeral Shaft Fracture
We report a case of a 29-year-old man who presented with a distal humeral shaft fracture sustained by blunt trauma. Physicalexamination and nerve conduction study were consistent with injury to the median and radial nerves proximal to theelbow. The patient underwent open reduction and internal fixation of the humeral shaft fracture with neurolysis of the medianand radial nerves. Repeat electrom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Electromyography and clinical neurophysiology
دوره 40 3 شماره
صفحات -
تاریخ انتشار 2000