Experimental investigation on mass transfer for regeneration of liquid desiccant
نویسندگان
چکیده
Desiccants can be used in conjunction with solar energy to provide a viable alternative to traditional air conditioning techniques. Liquid desiccant regeneration was proved to be an effective method to extract the moisture from solution with a relatively less energy in order to regenerate the desiccant. An experimental study was carried out to analyze the effect of temperature for regeneration process using an injected air through the liquid desiccant solution (calcium chloride dihydrate) by a dryer. Many tests with different operating conditions such as air temperature, humidity ratio, air velocity and solution level are investigated in order to demonstrate that this salt is capable to absorb moisture and can be regenerated at a low temperature. Experimental results showed that the mass transfer is affected by the air conditions. Also, the vapour pressure difference between the air and liquid desiccant surface is the driving force of the mass transfer process. In this analysis it was also determined that the CaCl2.2H2O could be regenerated at low temperature around 48 to 60°C hence the possibility of using the flat plate solar collectors for its regeneration and this salt can be used in a system (LDCS).
منابع مشابه
An investigation of heat and mass transfer enhancement of air dehumidification with addition of γ-Al2O3 nano-particles to liquid desiccant
This study introduces an experimental and theoretical investigation of the performance of a proposed air dehumidification system using a nanofluid of γ-alumina nano-particles in LiBr/H2O as a desiccant. Comparative experiments organized using a central composite design were carried out to evaluate the effects of six numerical factors (air velocity, desiccant flow rate, air humidity ratio, desic...
متن کاملRegeneration performance of liquid desiccant on the surface of a plate-type heat exchanger
Recently, there have been many studies on dehumidifiers with a low flow rate of liquid desiccant, in which a plate-type heat exchanger with internal cooling is adopted. If the low flow rate of a liquid desiccant maintains a thin liquid film on the heat exchanger surface, heat and mass transfer performance would improve, the stability of the liquid film would increase, and there would be no entr...
متن کاملTheoretical and Experimental Investigation of the Key Components for a Rotary Desiccant Wheel
This paper describes the theoretical and experimental investigations of the key components and also the performance analysis of a rotary wheel for using as a solid desiccant dehumidifier and also indirect evaporator cooling system. Solid desiccants have long been used in dehumidification and cooling systems for energy efficiency or reduce electricity. Although many mathematical models on th...
متن کاملThe Effect of Geometrical Characteristics of Desiccant Wheel on its Performance
Desiccant wheels are widely used in buildings to control humidity and reduce energy consumption. A model is presented based on transient coupled heat and mass transfer, to model, design and analyze the effects of geometrical characteristics of a honeycombed rotary desiccant wheel and its performance. Governing equations are solved numerically using finite volume method and the model is validate...
متن کاملExperimental Investigation of a New Enthalpy Exchanger with Low Absorbent Carryover Designed for Liquid Desiccant Dehumidification System
In this paper, the absorbent carryover effect in a designed counter-flow enthalpy exchanger is investigated. In a built prototype of the liquid desiccant dehumidifier, air and the absorbent solution are in contact and flow through a packed multi-channel polymer tower in a counter-flow pattern. To avoid the absorbent carryover, the tower is equipped with an eliminator. Experimental measurements ...