Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest.
نویسندگان
چکیده
INTRODUCTION The purpose of this pilot clinical study was to determine if a novel chest compression device would improve hemodynamics when compared to manual chest compression during cardiopulmonary resuscitation (CPR) in humans. The device is an automated self-adjusting electromechanical chest compressor based on AutoPulse technology (Revivant Corporation) that uses a load distributing compression band (A-CPR) to compress the anterior chest. METHODS A total of 31 sequential subjects with in-hospital sudden cardiac arrest were screened with institutional review board approval. All subjects had received prior treatment for cardiac disease and most had co-morbidities. Subjects were included following 10 min of failed standard advanced life support (ALS) protocol. Fluid-filled catheters were advanced into the thoracic aorta and the right atrium and placement was confirmed by pressure waveforms and chest radiograph. The coronary perfusion pressure (CPP) was measured as the difference between the aortic and right atrial pressure during the chest compression's decompressed state. Following 10 min of failed ALS and catheter placement, subjects received alternating manual and A-CPR chest compressions for 90 s each. Chest compressions were administered without ventilation pauses at 100 compressions/min for manual CPR and 60 compressions/min for A-CPR. All subjects were intubated and ventilated by bag-valve at 12 breaths/min between compressions. Epinephrine (adrenaline) (1mg i.v. bolus) was given at the request of the attending physician at 3-5 min intervals. Usable pressure signals were present in 16 patients (68 +/- 6 years, 5 female), and data are reported from those patients only. A-CPR chest compressions increased peak aortic pressure when compared to manual chest compression (153 +/- 28 mmHg versus 115 +/- 42 mmHg, P < 0.0001, mean +/- S.D.). Similarly, A-CPR increased peak right atrial pressure when compared to manual chest compression (129 +/- 32 mmHg versus 83 +/- 40 mmHg, P < 0.0001). Furthermore, A-CPR increased CPP over manual chest compression (20 +/- 12 mmHg versus 15 +/- 11 mmHg, P < 0.015). Manual chest compressions were of consistent high quality (51 +/- 20 kg) and in all cases met or exceeded American Heart Association guidelines for depth of compression. CONCLUSION Previous research has shown that increased CPP is correlated to increased coronary blood flow and increased rates of restored native circulation from sudden cardiac arrest. The A-CPR system using AutoPulse technology demonstrated increased coronary perfusion pressure over manual chest compression during CPR in this terminally ill patient population.
منابع مشابه
Improved hemodynamics with a novel chest compression device during treatment of inhospital cardiac arrest
Introduction Previous research has shown that increased coronary perfusion pressure (CPP) during cardiopulmonary resuscitation (CPR) correlates with increased coronary blood flow and improved survival from sudden cardiac arrest. The purpose of this clinical study was to determine if a novel chest compression device (AutoPulse, Revivant Corp) improves hemodynamics during CPR when compared with m...
متن کاملFuture Treatment of Acute Cardiac Collapse - A Role for Percutaneous Circulatory Assist Devices
1.1 Acute cardiac collapse Patients with cardiogenic shock and cardiac arrest still have a very poor prognosis despite recent improvements in treatment algorithms. Acute coronary ischemia and myocardial infarction (AMI) is the most frequent cause of cardiogenic shock and cardiac arrest. Improved survival has been shown for patients with AMI treated with urgent coronary revascularization. Also, ...
متن کاملA feasibility study of cerebral oximetry during in-hospital mechanical and manual cardiopulmonary resuscitation*.
OBJECTIVE A major hurdle limiting the ability to improve the quality of resuscitation has been the lack of a noninvasive real-time detection system capable of monitoring the quality of cerebral and other organ perfusion, as well as oxygen delivery during cardiopulmonary resuscitation. Here, we report on a novel system of cerebral perfusion targeted resuscitation. DESIGN An observational study...
متن کاملHemodynamic-directed cardiopulmonary resuscitation during in-hospital cardiac arrest.
Cardiopulmonary resuscitation (CPR) guidelines assume that cardiac arrest victims can be treated with a uniform chest compression (CC) depth and a standardized interval administration of vasopressor drugs. This non-personalized approach does not incorporate a patient's individualized response into ongoing resuscitative efforts. In previously reported porcine models of hypoxic and normoxic ventr...
متن کاملStenting a moving target. Neurological and hemodynamic recovery after 80 minutes of CPR using an automated chest compression device to facilitate percutaneous coronary intervention.
Despite significant advances in the science of resuscitation, survival to discharge after an in-hospital cardiac arrest in the catheterization laboratory remains poor. Clinicians face the challenges of performing CPR during procedures to address the cause of the arrest and the limitations of prolonged manual CPR. In this article we describe the first case of a patient presenting in cardiogenic ...