The radiographic evaluation of keeled and pegged glenoid component insertion.

نویسندگان

  • Mark D Lazarus
  • Kirk L Jensen
  • Carleton Southworth
  • Frederick A Matsen
چکیده

BACKGROUND Radiolucent lines about the glenoid component of a total shoulder replacement are a common finding, even on initial postoperative radiographs. The achievement of complete osseous support of the component has been shown to decrease micromotion. We evaluated the ability of a group of experienced shoulder surgeons to achieve complete cementing and support in a series of patients managed with keeled and pegged glenoid components. METHODS We reviewed the initial postoperative radiographs of 493 patients with primary osteoarthritis who had been managed with total shoulder arthroplasty by seventeen different surgeons. One hundred and sixty-five patients were excluded because of inadequate radiographs, leaving 328 patients available for review. Of these, thirty-nine patients had a keeled component and 289 had a pegged component. The method of Franklin was used to grade the degree of radiolucency around the keeled components, and a modification of that method was used to grade the degree of radiolucency around the pegged components. The efficacy of component seating on host subchondral bone was evaluated with a newly constructed five-grade scale based on the percentage of the component that was supported by subchondral bone. Each radiograph was graded four times, by two separate reviewers on two separate occasions. RESULTS Radiolucencies were extremely common, with only twenty of the 328 glenoids demonstrating no radiolucencies. On a numeric scale (with 0 indicating no radiolucency and 5 indicating gross loosening), the mean radiolucency score was 1.8 +/- 0.9 for keeled components and 1.3 +/- 0.9 for pegged components (p = 0.0004). After defining categories of "better" and "worse" cementing, we found that pegged components more commonly had "better cementing" than did keeled components (p = 0.0028). Incomplete seating was also common, particularly among patients with keeled components. Ninety-five of the 121 pegged components that had been inserted by the most experienced surgeon had "better cementing," compared with eighty-five of the 168 pegged components that had been inserted by the remaining surgeons (p < 0.00001). CONCLUSIONS Perfectly cementing and seating a glenoid replacement is a difficult task. Radiolucencies and incomplete component seating occur more frequently in association with keeled components compared with pegged components. Surgeon experience may be an important variable in the achievement of a good technical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic comparison of pegged and keeled glenoid components using modern cementing techniques: a prospective randomized study.

BACKGROUND Modern cementing techniques have improved glenoid fixation, reduced glenoid lucency seen with keeled components, and may eliminate differences attributable to glenoid design. The purpose of this study was to determine the effect of glenoid design on immediate and follow-up radiographic lucency of pegged and keeled glenoid components, using modern cementing techniques. MATERIAL AND ...

متن کامل

Radiographic Evaluation of Glenoid Components and its Survivorship

Introduction: This study evaluated the survivorship of pegged versus keeled cemented, all-polyethylene glenoid components using modern cementing and glenoid preparation techniques. Survival of glenoid design was determined according to severity of radiolucencies on follow-up radiographs. Methods: Between April 22, 1999, and February 17, 2009, retrospective chart review was performed on 194 tota...

متن کامل

No correlation between radiolucency and biomechanical stability of keeled and pegged glenoid components

BACKGROUND The purpose of this study was to examine biomechanical properties and the degree of radiolucency of two cemented basic glenoid designs for total shoulder arthroplasty. Our hypothesis was that a component with increased micro-motion in the laboratory at time zero would also exhibit a greater amount of radiolucency in patients at a minimum of 2 years post total shoulder arthroplasty. ...

متن کامل

In vitro measurement of temperature changes during implantation of cemented glenoid components

BACKGROUND AND PURPOSE It is unclear whether the increase in temperature during cement curing may cause osteonecrosis, leading to loosening of the glenoid component in shoulder arthroplasty. We therefore analyzed the temperature during implantation of cemented glenoid implants. METHODS 8 keeled and 8 pegged glenoids were implanted in standardized fashion in 8 pairs of scapulas. Temperature an...

متن کامل

Incidence of early development of radiolucent lines in keeled polyethylene glenoid components after total shoulder arthroplasty.

Glenoid loosening after total shoulder arthroplasty (TSA) remains a major concern. The purpose of this study was to determine the incidence of radiolucent lines (RLLs) after TSA performed with modern glenoid bone preparation and cement techniques for keeled-back glenoid components. One hundred ten consecutive patients with osteoarthritis were included in this study. Patients had undergone prima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 84-A 7  شماره 

صفحات  -

تاریخ انتشار 2002