An investigation into the mechanical characteristics of select self-ligated brackets at a series of clinically relevant maximum torquing angles: loading and unloading curves and bracket deformation.

نویسندگان

  • Thomas W Major
  • Jason P Carey
  • David S Nobes
  • Giseon Heo
  • Garrett W Melenka
  • Paul W Major
چکیده

Edgewise orthodontic treatment utilizes a force couple in order to achieve labial-lingual tooth angulation. Two self-ligating brackets (Damon Q and Speed) were examined across a range of clinically relevant torques in order to assess the loading and unloading curves and bracket deformation. A previously developed torquing and load measurement system was utilized to rotate a 0.199 × 0.25 in stainless steel wire in a fixed bracket slot to the following angles: 16, 20, 24, 28, 32, and 40 degrees. The torque on the bracket was measured during both wire loading and unloading cycles. The torque play for the Damon brackets was determined to increase by less than 0.4 degrees when torqued to 70 Nmm, whereas the increase for the Speed brackets was 2.1 degrees at the same torque magnitude. The deformation curves for the Damon and Speed brackets were found to be different for loading and unloading. Speed brackets were found to start to plastically deform when torqued to 24 degrees (26 Nmm of torque), while Damon brackets did not plastically deform until 28 degrees (38 Nmm of torque). Damon brackets were found not to plastically deform as easily and to have a smaller increase in torque play than Speed brackets. Both the Damon and the Speed brackets demonstrated minimal effect of plastic deformation and torque play at maximum angles of twist less than 20 degrees. Torque measured in the brackets was different for loading and unloading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of deformation and torque expression of the orthos and orthos Ti bracket systems.

Orthodontic torque expression is the result of axial rotation of rectangular archwires within a rectangular bracket slot. This study investigates the effect of bracket material on torque expression. Torque exerted by a rotating archwire on each bracket will be measured as well as the relative deformation of each bracket slot. A total of 60 tests were performed where archwires were rotated withi...

متن کامل

بررسی مقاومت اصطکاکی سیم نیکل تیتانیوم ارتودنسی در زوایای مختلف قرارگیری براکت و سیم

Background and Objective: Resistance to sliding is a combination of friction and binding. When the angle between the bracket and the wire exceeds the critical angle, binding occurs. The influence of angulation is confounding because of certain inherent physical characteristics of materials. The present study was carried out to evaluate the effect of wire- bracket angulation on resistance to sli...

متن کامل

Comparing Streptococcus Mutans Adhesion by Using Different Orthodontic Bracket Ligations: An In Vitro Study

Introduction: Orthodontic treatments and brackets application with various ligature methods have increased worldwide, but the growth rate and mechanism of microorganism adhesion to these ligatures is not fully discovered. The current study aimed to compare the level of streptococcus mutans adhesion to three different ligation methods. Materials and Methods: This in vitro study was performed on...

متن کامل

Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets.

The purpose of this research was to investigate the torque capacity of active and passive self-ligating brackets compared with metallic, ceramic, and polycarbonate edgewise brackets. Six types of orthodontic brackets were included in the study: the self-ligating Speed and Damon2, the stainless steel (SS), Ultratrimm and Discovery, the ceramic bracket, Fascination 2, and the polycarbonate bracke...

متن کامل

Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements.

OBJECTIVE The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip. METHODS Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 35 6  شماره 

صفحات  -