Three dimensional inertial sensing of foot movements for automatic tuning of a two-channel implantable drop-foot stimulator.
نویسندگان
چکیده
A three dimensional inertial sensing system for measuring foot movements during gait is proposed and tested. It can form the basis for an automated tuning system for a two-channel implantable drop-foot stimulator. The foot orientation and position during the swing phase of gait can be reconstructed on the basis of three-dimensional measurement of acceleration and angular velocity, using initial and final conditions during mid-stance. The foot movements during gait of one stroke person using the implanted two-channel stimulator were evaluated for several combinations of stimulation parameters for both channels. The reconstructed foot movements during gait in this person indicated that the channel stimulating the deep peroneal nerve contributes mainly to dorsiflexion and provides some reduction of inversion seen without stimulation, while the channel activating the superficial peroneal nerve mainly provides additional reduction of inversion. This agrees with anatomical knowledge about the function of the muscles activated by both branches of the peroneal nerve. The inertial sensor method is expected to be useful for the clinical evaluation of foot movements during gait supported by the two-channel drop-foot stimulator. Furthermore, it is expected to be applicable for the automated balancing of the two stimulation channels to ensure optimal support of gait.
منابع مشابه
An Implantable Foot Drop Stimulator
A novel partially implantable system for correction of foot drop has been developed and is being tested in three volunteer subjects. The system consists of a two-channel implantable stimulator, a multi-polar nerve cuff electrode implanted on the peroneal nerve proximal to the knee, and an external system including battery, control and telemetry unit and a heel switch. Although the work is still...
متن کاملEffects of an implantable two-channel peroneal nerve stimulator versus conventional walking device on spatiotemporal parameters and kinematics of hemiparetic gait.
OBJECTIVE The aims of this study were: (i) to compare the neuro-prosthetic effect of implantable peroneal nerve stimulation to the orthotic effect of a standard of care intervention (no device, shoe or ankle foot orthosis) on walking, as assessed by spatiotemporal parameters; and (ii) to examine whether there is evidence of an enhanced lower-limb flexion reflex with peroneal nerve stimulation a...
متن کاملA randomized controlled trial of an implantable 2-channel peroneal nerve stimulator on walking speed and activity in poststroke hemiplegia.
OBJECTIVE To determine the effect of a new implantable 2-channel peroneal nerve stimulator on walking speed and daily activities, in comparison with the usual treatment in chronic stroke survivors with a drop foot. DESIGN Randomized controlled trial. SETTING All subjects were measured 5 times in the gait laboratory. PARTICIPANTS Twenty-nine stroke survivors with chronic hemiplegia with dr...
متن کاملBrain plasticity after implanted peroneal nerve electrical stimulation to improve gait in chronic stroke patients: Two case reports.
BACKGROUND Recent studies have shown that stimulation of the peroneal nerve using an implantable 4-channel peroneal nerve stimulator could improve gait in stroke patients. OBJECTIVES To assess structural cortical and regional cerebral metabolism changes associated with an implanted peroneal nerve electrical stimulator to correct foot drop related to a central nervous system lesion. METHODS ...
متن کاملThe sensitivity and selectivity of an implantable two-channel peroneal nerve stimulator system for restoration of dropped foot.
The objective of this study was to evaluate the stimulation responses on each channel of an implantable two-channel stimulator that stimulates the peroneal nerve branches innervating the muscles for dorsiflexion and eversion movements. Currently five Dutch patients and five English patients have been implanted with this system. Isometric ankle torque measurements were carried out in the patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 25 1 شماره
صفحات -
تاریخ انتشار 2003