Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

نویسندگان

  • Sebastian Weingärtner
  • Nadja M Meßner
  • Frank G Zöllner
  • Mehmet Akçakaya
  • Lothar R Schad
چکیده

PURPOSE To study the feasibility of black-blood contrast in native T1 mapping for reduction of partial voluming at the blood-myocardium interface. METHODS A saturation pulse prepared heart-rate-independent inversion recovery (SAPPHIRE) T1 mapping sequence was combined with motion-sensitized driven-equilibrium (MSDE) blood suppression for black-blood T1 mapping at 3 Tesla. Phantom scans were performed to assess the T1 time accuracy. In vivo black-blood and conventional SAPPHIRE T1 mapping was performed in eight healthy subjects and analyzed for T1 times, precision, and inter- and intraobserver variability. Furthermore, manually drawn regions of interest (ROIs) in all T1 maps were dilated and eroded to analyze the dependence of septal T1 times on the ROI thickness. RESULTS Phantom results and in vivo myocardial T1 times show comparable accuracy with black-blood compared to conventional SAPPHIRE (in vivo: black-blood: 1562 ± 56 ms vs. conventional: 1583 ± 58 ms, P = 0.20); Using black-blood SAPPHIRE precision was significantly lower (standard deviation: 133.9 ± 24.6 ms vs. 63.1 ± 6.4 ms, P < .0001), and blood T1 time measurement was not possible. Significantly increased interobserver interclass correlation coefficient (ICC) (0.996 vs. 0.967, P = 0.011) and similar intraobserver ICC (0.979 vs. 0.939, P = 0.11) was obtained with the black-blood sequence. Conventional SAPPHIRE showed strong dependence on the ROI thickness (R2 = 0.99). No such trend was observed using the black-blood approach (R2 = 0.29). CONCLUSION Black-blood SAPPHIRE successfully eliminates partial voluming at the blood pool in native myocardial T1 mapping while providing accurate T1 times, albeit at a reduced precision. Magn Reson Med 78:484-493, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Black-blood T1 mapping at 3T: Reduced partial-voluming using adiabatic MSDE preparation

Background Myocardial T1 mapping in pathologies with decreased myocardial wall thickness such as dilated cardiomyopathy (DCM) is strongly impaired by partial-voluming from the neighboring blood pools [Kellman et al., JCMR2014]. Significant differences between the T1 times in myocardium and blood lead to decreased accuracy in the presence of partial-voluming. This causes sensitivity to the regio...

متن کامل

Non-selective double inversion recovery pre-pulse for flow-independent black blood myocardial viability imaging

Introduction & Purpose: MRI late gadolinium enhancement (LGE) using the inversion-recovery (IR) sequence is the current gold standard for the assessment of myocardial viability. Although it achieves high contrast between infarct and normal myocardium, there is often poor infarct-to-blood contrast. Flow-dependent and diffusion-prepared black-blood LGE techniques have previously been described. T...

متن کامل

Fat-water separated myocardial T1 mapping with IDEAL-T1 saturation recovery gradient echo imaging

Background Myocardial T1 mapping is emerging as powerful tool for tissue characterization, however the presence of intramyocardial or epicardial fat can contaminate T1 values through partial voluming, or preclude analysis, particularly in areas of infarct or thin walled myocardium, such as the right ventricle. We propose and evaluate a new combined fat-water separated saturation-recovery imagin...

متن کامل

Native myocardial T1 precision is increased by correcting for myocardial blood variation

Background Native myocardial T1 mapping with CMR has emerged as a new diagnostic tool in heart disease. However, myocardial T1 will be affected by the T1 of blood present in the myocardium. To explore this, as there is no easy way to manipulate blood in isolation, we hypothesized that the population standard deviation (SD) for myocardial T1 could be reduced by correcting the myocardial T1 for c...

متن کامل

Effect of changes to Modified Look-Locker Inversion (MOLLI) sequence on T1 Mapping at 3.0 Tesla in healthy volunteers

Background Diffuse myocardial fibrosis may be quantified with cardiovascular magnetic resonance (CMR) by calculating extra-cellular volume (ECV) from native and post-contrast T1 values. T1 values are affected by field strength and acquisition sequence. The Modified Look Locker Inversion Recovery (MOLLI) method of T1 mapping is a widely used approach, but many different acquisition schemes have ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 78 2  شماره 

صفحات  -

تاریخ انتشار 2017