Intentional Fracture of Maximally Dilated Balloon-Expandable Pulmonary Artery Stents Using Ultra-High-Pressure Balloon Angioplasty: A Preliminary Analysis.

نویسندگان

  • Brian H Morray
  • Doff B McElhinney
  • Audrey C Marshall
  • Diego Porras
چکیده

BACKGROUND Treatment with endovascular stents has become increasingly common for the management of vascular stenosis in congenital heart disease. The use of stents in smaller patients has been tempered by concerns about the potential for stent expansion to accommodate somatic growth. One solution to limited stent diameter is the intentional fracture of maximally dilated stents, which can be accomplished using ultra-high-pressure (UHP) balloons. METHODS AND RESULTS This retrospective cohort study compared procedural characteristics and adverse events between a cohort of patients with branch pulmonary artery (PA) stents who underwent stent fracture using UHP balloons and control patients who underwent UHP redilation of previously placed PA stents without stent fracture between 2004 and 2014. Two control patients were selected for every case. Thirty-three PA stents were fractured in 31 patients with a median of 10 years after initial stent placement. The median balloon:waist ratio was 1.17 (1-1.71), and the median inflation pressure was 20 (8-30) atm. There were significant reductions in pressure gradient after angioplasty, with no difference in postangioplasty gradients between cases and controls. There were no major PA complications in the stent fracture group and no difference in the number of adverse events between the 2 groups. CONCLUSIONS In this small series, PA stent fracture using UHP balloon angioplasty was feasible and did not result in major complications although predictors of successful fracture were not identified. Intentional fracture with UHP balloon angioplasty may be considered when treating stents that have become restrictive despite maximal dilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-High-Pressure Balloon Angioplasty for Treatment of Resistant Stenoses Within or Adjacent to Previously Implanted Pulmonary Arterial Stents Brief title: Ultra-high pressure redilation of PA stents

Background. Stents are essential tools in the management of pulmonary arterial (PA) stenosis in patients with congenital heart disease. Although stents can usually be reexpanded as children grow, resistant instent or peri-stent obstruction can complicate the management of PA stents. Angioplasty with ultra-highpressure (UHP) balloons may facilitate successful treatment of stent-associated PA ste...

متن کامل

Ultra-high-pressure balloon angioplasty for treatment of resistant stenoses within or adjacent to previously implanted pulmonary arterial stents.

BACKGROUND Stents are essential tools in the management of pulmonary arterial (PA) stenosis in patients with congenital heart disease. Although stents can usually be reexpanded as children grow, resistant in-stent or peri-stent obstruction can complicate the management of PA stents. Angioplasty with ultra-high-pressure (UHP) balloons may facilitate successful treatment of stent-associated PA st...

متن کامل

Transcatheter Stent Therapy in Children: An Update

To address elastic recoil of vessel wall and intimal dissection that can follow balloon angioplasty, stents have been designed and these appear to produce more effective relief of obstruction. Of the two types of stents, namely, balloon expandable and self expandable, balloon expandable stents are most commonly used in children. The usefulness of stents in the management of vascular obstructive...

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Coarctoplasty with self-expandable stent implantation for treatment of coarctation of aorta in adults.

BACKGROUND Balloon angioplasty for treatment of coarctation of the aorta in adults, though promising, is sometimes limited by significant residual gradient (> 20 mmHg). Few studies have been reported on use of balloon-expandable stents in such a situation. We evaluated the use of self-expandable stents in patients with coarctation of the aorta. METHODS Eight hypertensive patients (age 15 to 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 2016