Anterior Cruciate Ligament Reconstruction With Autologous Hamstring

نویسندگان

  • Brian M. Grawe
  • Phillip N. Williams
  • Alissa Burge
  • Marcia Voigt
  • David W. Altchek
  • Jo A. Hannafin
  • Answorth A. Allen
چکیده

BACKGROUND Recent clinical investigations have identified inadequate autograft hamstring graft diameter (<8 mm) to be predictive of failure after reconstruction of the anterior cruciate ligament (ACL). PURPOSE/HYPOTHESIS The objective of this study was to determine the utility of preoperative magnetic resonance imaging (MRI) variables of the hamstring tendons for the prediction of graft diameter at the time of surgery. The hypothesis was that cross-sectional area (CSA) of the hamstring tendon measured on MRI could accurately predict graft diameter, and threshold measurements could be established to predict graft diameter at the time of surgery. STUDY DESIGN Cohort study (diagnosis); Level of evidence, 2. METHODS A total of 84 consecutive skeletally mature patients prospectively enrolled in our ACL reconstruction patient registry were identified for study purposes. Patients were included if they underwent an MRI of the affected knee at our institution prior to ACL reconstruction with hamstring (HT) autograft. Graft preparation was performed via a standard quadrupled hamstring technique after harvesting both the gracilis and semitendinosus (4-GST). The smallest diameter end of the HT autograft was then utilized for measurement analysis. Total CSA was calculated for both hamstring tendons using the "region of interest tool" on the corresponding proton density-weighted axial image of the knee at the widest condylar dimension. Three independent reviewers measured the MRI scans so that intra- and interrater reliability of the measurements could be determined. A trend analysis was then undertaken to establish correlations between the MRI CSA and graft diameter. Predictive analysis was then performed to establish threshold MRI measurement values for specific graft diameters and determine whether any patient-specific factors would affect graft diameter (age, sex, and body mass index). RESULTS Mean patient age at the time of surgery was 36 years (range, 11-57 years). Intra- and interrater reliability measurements achieved near-perfect agreement for CSA measurements, with intraclass correlation coefficients (ICCs) of 0.994 and 0.932, respectively. Trend analysis demonstrated that increasing CSA correlated well with increasing overall diameter of the graft (P < .001). Receiver operating characteristic (ROC) curves were generated to evaluate threshold CSA measurements for various graft diameters. Maximum sensitivity values of 21.64, 25.25, and 28.256 mm(2) were established for the respective graft diameters of 8, 9, and 10 mm in the 4-GST group. Independent patient factors of younger age, shorter stature, and female sex were significantly associated with graft diameter (P = .019, .034, and .028, respectively). CONCLUSION Preoperative MRI can be used to accurately predict quadrupled hamstring autograft diameter at the time of surgery. A total cross-sectional area of >22 mm(2) can reliably provide a graft diameter of >8 mm at the time of surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transphyseal Reconstruction of the Anterior Cruciate Ligament Using Hamstring Autograft in Skeletally Immature Adolescents

Eleven skeletally immature adolescents underwent anterior cruciate ligament reconstruction using a transphyseal tibial and femoral tunnel. An autologous quadrupled hamstring tendon was used in all cases and the average follow-up was 77.7 months. Clinical results were evaluated using Lysholm knee scores and a return to pre-injury sports activities. Radiological results were evaluated using side-...

متن کامل

A randomized comparison of patellar tendon and hamstring tendon anterior cruciate ligament reconstruction.

BACKGROUND Patellar and hamstring tendon autografts are the most frequently used graft types for anterior cruciate ligament reconstruction, but few direct comparisons of outcomes have been published. HYPOTHESIS There is no difference in outcome between the two types of reconstruction. STUDY DESIGN Prospective randomized clinical trial. METHODS After isolated anterior cruciate ligament rup...

متن کامل

Clinical Outcome of Anatomical Transportal Arthroscopic Anterior Cruciate Ligament Reconstruction with Hamstring Tendon Autograft

Background: Good clinical outcome and return to sport and daily functions after anatomical arthroscopic anteriorcruciate ligament (ACL) reconstruction is goal standard in this surgery. but to date, there are different challengingissues between orthopedic surgeons regarding graft selection and surgical techniques.Methods: We retrospectively reviewed the patients who underwent anatomical arthrosc...

متن کامل

Biologic and Mechanical Augmentation in Anterior Cruciate Ligament Reconstruction: Fibrin Clot Augmentation of 5-Strand Hamstring Autograft

Hamstring autografts in anterior cruciate ligament reconstruction have an excellent clinical track record, but some patients have hamstring tendons that yield grafts of smaller diameter, which has been shown to be a significant risk factor for worse outcomes and graft failure. Some authors have advocated augmentation with allograft in these patients. Tripling the semitendinosus yields a complet...

متن کامل

Single-tunnel double-bundle anterior cruciate ligament reconstruction with anatomical placement of hamstring tendon graft: can it restore normal knee joint kinematics?

BACKGROUND Anatomical reconstruction techniques that can restore normal joint kinematics without increasing surgical complications could potentially improve clinical outcomes and help manage anterior cruciate ligament injuries more efficiently. HYPOTHESIS Single-tunnel double-bundle anterior cruciate ligament reconstruction with anatomical placement of hamstring tendon graft can more closely ...

متن کامل

Dynamic function after anterior cruciate ligament reconstruction with autologous patellar tendon.

The purpose of this study was to dynamically assess the functional outcome of patients who had undergone successful anterior cruciate ligament reconstruction using an autologous patellar tendon technique and to determine whether their dynamic knee function was related to quadriceps and hamstring muscle strength. The knee kinematics and kinetics of 22 subjects who had undergone anterior cruciate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016