The VITEK 2 (bioMérieux Inc., Hazelwood, MO) automated system employs an advanced expert system (AES) analyzing antimicrobial susceptibility test results according to the bacterial species (2). According to the AES, the piperacillin susceptibilities of all Klebsiella spp. are converted to resistance even though the automated MICs determined for their isolates are low. In contrast, other automated systems do not convert the piperacillin susceptibilities of Klebsiella spp. to resistance. In addition, there is no explanation in the Clinical and Laboratory Standards Institute (CLSI) guideline in this regard, and the U.S. FDA product (http://www.fda.gov) package insert lists Klebsiella as an organism for which piperacillin use is indicated [Pipracil (piperacillin) for injection, package insert; Wyeth Pharmaceuticals Inc., Philadelphia, PA]. In this study, we intended to evaluate the appropriateness of this reporting system in comparison with results for other Enterobacteriaceae, for which the susceptibility results are not converted to resistance to piperacillin. Between January and June 2007, 135 consecutive, nonduplicate Klebsiella spp. (120 Klebsiella pneumoniae isolates and 15 Klebsiella oxytoca isolates) were collected. The piperacillin MICs were determined by the agar dilution method according to the CLSI guidelines (7) and compared with VITEK 2 automated MIC determinations and interpretative susceptibilities determined by AES. For 107 isolates susceptible to piperacillin as determined by VITEK 2, PCRs for the blaTEM (6), blaSHV (3), and blaOXA (1) genes were performed using whole DNAs extracted by boiling at 95°C for 10 min and a PTC-100 thermal cycler (MJ Research Inc., Watertown, MA). For 50 members of the family Enterobacteriaceae (10 Enterobacter cloacae isolates, 6 Enterobacter aerogenes isolates, 19 Escherichia coli isolates, 7 Serratia marcescens isolates, and 8 Proteus mirabilis isolates) susceptible to piperacillin by VITEK 2, agar dilution MICs and PCRs for the above genes were also performed. For 20 selected Klebsiella isolates susceptible to piperacillin according to both VITEK 2 automated MICs and agar dilution MICs and for 50 members of the family Enterobacteriaceae, the inoculum effect (more than three twofold increases in MIC when tested with 10 CFU/spot instead of 10 CFU/ spot) was investigated. The results of VITEK 2 automated MIC determinations, agar dilution MIC determinations, and AES interpretative reading regarding piperacillin for Klebsiella spp. are listed in Table 1. The concordance rate between automated MICs and agar dilution MICs for 135 Klebsiella isolates was 96.3%, and all 20 selected Klebsiella isolates revealed an inoculum effect. Of the 95 K. pneumoniae isolates found to be susceptible to piperacillin by VITEK 2, 92 (96.8%) harbored blaSHV genes and the remaining 3 isolates did not harbor any of the blaSHV, blaTEM, or blaOXA genes. In contrast, none of the 12 K. oxytoca isolates harbor any of these genes. Agar dilution MICs were within the susceptible range for 49 members of the family Enterobacteriaceae, and 1 E. coli isolate had a MIC of 32 g/ml. The inoculum effect was found for all of them, but only blaTEM was detected in four isolates. Livermore et al. reported that the use of any penicillin except temocillin against Klebsiella spp. should be discouraged, because Klebsiella spp. have classical low-level SHV-1 or K1 -lactamase (4), and the inoculum effect was observed with piperacillin and other ureidopenicillins tested against them (5). However, in this study, the inoculum effect for piperacillin was not related to the species or the presence of blaSHV, blaTEM, or blaOXA. Although more studies including use of an animal infection model are needed, conversion of piperacillin susceptibility to resistance for Klebsiella spp. must be reconsidered or used with caution.
منابع مشابه
Characterization of Klebsiella isolates by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and determination of antimicrobial resistance with VITEK 2 advanced expert system (AES).
BACKGROUND/AIM The purpose of the study was to evaluate the performance of the VITEK mass spectrometry (MS) (bioMérieux, France) system for the identification of Klebsiella spp. isolated from different sources. Moreover, while assessing the ability of the VITEK 2 automated expert system (AES) to recognize antimicrobial resistance patterns, the researchers have extended the study to compare VITE...
متن کاملAustralian Group on Antimicrobial Resistance Community-onset Gram-negative Surveillance Program annual report, 2010.
The Australian Group on Antimicrobial Resistance (AGAR) performs regular period-prevalence studies to monitor changes in antimicrobial resistance in selected enteric Gram-negative pathogens. The 2010 survey focussed on community-onset infections, examining isolates from urinary tract infections from patients presenting to outpatient clinics, emergency departments or to community practitioners. ...
متن کاملSusceptibility Testing of Pseudomonas Aeruginosa by the Vitek 2 System: a Comparison with Etest Results. Susceptibility Testing of Pseudomonas Aeruginosa by the Vitek 2 System: a Comparison with Etest Results
P. aeruginona infections need accurate antimicrobial susceptibility data, as treatment mainly relies on antibiotic effi ciency in debilitated patients. Vitek 2, a popular automated susceptibility testing method, was compared with Etest to assess its reliability on 150 Belgian P. aeruginonas isolates. Vitek 2 and Etest exhibited a high degree of concordance, but some discrepancies in clinical ca...
متن کاملEvaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gram-negative bacilli from positive blood cultures.
This study explores the possibility of combining the BacT/Alert Microbial Detection System with the VITEK 2 system to achieve rapid bacterial identification and susceptibility testing. Direct inoculation of bacterial suspension to the VITEK 2 ID-GNB card and AST-NO09 card was made by differential centrifugation of blood cultures of organisms with gram-negative enteric bacillus-like morphology. ...
متن کاملCarbapenem Resistance in Klebsiella pneumoniae Not Detected by Automated Susceptibility Testing
Detecting beta-lactamase-mediated carbapenem resistance among Klebsiella pneumoniae isolates and other Enterobacteriaceae is an emerging problem. In this study, 15 blaKPC-positive Klebsiella pneumoniae that showed discrepant results for imipenem and meropenem from 4 New York City hospitals were characterized by isoelectric focusing; broth microdilution (BMD); disk diffusion (DD); and MicroScan,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 52 6 شماره
صفحات -
تاریخ انتشار 2008