Effect of age on the comparability of bispectral and state entropy indices during the maintenance of propofol-sufentanil anaesthesia.

نویسندگان

  • I Aimé
  • E Gayat
  • C Fermanian
  • F Cook
  • C Peuch
  • P A Laloë
  • J Mantz
  • M Fischler
چکیده

BACKGROUND Manufacturers recommend maintaining anaesthesia at a bispectral index (BIS) or state entropy (SE) index value between 40 and 60. METHODS We prospectively studied 102 patients receiving propofol-sufentanil anaesthesia administered by anaesthetists blinded to these indices. The main endpoint was crude agreement (P(0)), defined as the proportion of agreement between BIS and SE index among three categories: <40, between 40 and 60, and >60. Discrepancies in recommendation (DR) were also considered. A DR is type 1 if BIS or SE is <40, while the other is simultaneously >60. A DR is type 2 when BIS and SE index values are on different sides of a threshold (40 or 60) with three subtypes according to the magnitude of their difference. A linear multiple regression was performed to identify covariates that are independently associated with P(0). RESULTS In total, 12 147 pairs of values were studied. P(0) was 59.9 (24.5%) [mean (sd)]. Thirty-three patients presented more than 50% discordant pairs and only seven patients presented more than 95% concordant pairs. Type 1 DR occurred in only 1.1% of all the pairs. The median (inter-quartile range) number of type 2 DR varied from 5 (3-8) to 2 (1-3) according to the degree of difference. Multivariate analysis showed that age (P=0.0004) and electrode position (P=0.0084) were independently associated with P(0). An increase in the age of 10 yr decreases P(0) by 5%. CONCLUSIONS The agreement between BIS and SE indices is moderate and deteriorates as patients' age increases. This study cannot determine which index is best adapted for elderly patients. Additional work comparing both indices with raw EEG traces is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia.

BACKGROUND beta1-Adrenoceptor antagonists suppress the haemodynamic and arousal responses to tracheal intubation. The Entropy Module shows two spectral entropy-based indices, response entropy (RE) and state entropy (SE). The difference between RE and SE (RE-SE) may reflect nociception during general anaesthesia. In the present study, we investigated the effect of landiolol on entropy indices in...

متن کامل

EEG-based indices of anaesthesia: correlation between bispectral index and patient state index?

BACKGROUND AND OBJECTIVE Both the bispectral and the patient state indices are derived from the electroencephalogram and have been proposed as a measure of the same clinical target, the hypnotic component of anaesthesia. The present study evaluated whether there is concordance between the bispectral and the patient state indices with regard to end-points measured simultaneously in patients unde...

متن کامل

Bispectral and spectral entropy indices at propofol-induced loss of consciousness in young and elderly patients.

BACKGROUND Bispectral (BIS) and state/response entropy (SE/RE) indices have been widely used to estimate depth of anaesthesia and sedation. In adults, independent of age, adequate and safe depth of anaesthesia for surgery is usually assumed when these indices are between 40 and 60. Since the EEG is changing with increasing age, we investigated the impact of advanced age on BIS, SE, and RE indic...

متن کامل

Effects of fentanyl, alfentanil, remifentanil and sufentanil on loss of consciousness and bispectral index during propofol induction of anaesthesia.

The bispectral index (BIS) and a sedation score were used to determine and compare the effect of propofol in the presence of fentanyl, alfentanil, remifentanil and sufentanil. Seventy-five non-premedicated patients were assigned randomly into five groups (15 in each) to receive fentanyl, alfentanil, remifentanil, sufentanil or placebo. Opioids were administered using a target-con-trolled infusi...

متن کامل

Rocuronium dose-dependently suppresses the spectral entropy response to tracheal intubation during propofol anaesthesia.

BACKGROUND The Entropy Module anaesthesia monitor displays two spectral entropy-based indices, response entropy (RE) and state entropy (SE). The difference between RE and SE (RE-SE), which mainly reflects electromyography activation, is thought to indicate the adequacy of antinociception. Little is known, however, about the effects of neuromuscular blocking agents on the RE-SE. We investigated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 108 4  شماره 

صفحات  -

تاریخ انتشار 2012