Metallosis in an apparently well fixed total knee replacement

نویسندگان

  • P Mukherjee
  • M Ashworth
چکیده

One of the findings of prosthetic failure seen either on pre operative radiograph or at surgery is metallosis. To our knowledge, this has not been described in an apparently well-fixed noninfected prosthetic joint. Metallosis can be due to polyethylene bearing wear resulting in metal on metal wear and has been seen with macro motion of prosthesis against underlying cement or bone1. CASE REPORT An 80-year-old female presented with knee discomfort shortly after total knee replacement on same side. At two years, this discomfort deteriorated following a fall. On examination, the right knee had tenderness over the distal femoral bone/ prosthesis interface and patello-femoral crepitus was noted. Blood tests did not show any signs of infection. Radiograph of the knee replacement was reported to be within normal limits2. A bone scan was reported as normal3. Because of ongoing pain, the decision to explore the total joint replacement with possibility of revision was made. At exploration of the total knee replacement signs of metallosis were found adjacent to both the femoral and tibial components (Fig.1 & 2). Figure 1 Figure 1 Metallosis in an apparently well fixed total knee replacement 2 of 3 Figure 2 Figure 2 There were no obvious signs of loosening (bubble test was negative). Although the components appear well fixed the polyethylene was considered compromised by the metal debris and revision was undertaken. The extraction of the prosthesis was very easy and there was deficient cementation in a quadrant on each component allowing macro motion and with metallosis formed in these areas, we interpreted this as indicating the joint replacement was loose. The tissue samples taken for microbiology did not grow any micro organisms. The histological examinations of the tissue samples did show signs of metal in the synovium but no polymorphs were seen4. Following the revision surgery patient did well and symptom of pain has completely settled. DISCUSSION Metallosis is usually not seen in a well fixed knee replacement but in a loose knee replacement1. Finding of metallosis in an apparently well fixed knee replacement without poly ethylene wear should alert the surgeon to the possibilities that the component(s) is (are) loose. Further we believe that metallosis is an indication for revision as it is the sign of a failing or failed knee replacement. CORRESPONDENCE TOMr. P Mukherjee MRCS Senior SHO Trauma andOrthopaedics Torbay Hospital South Devon Healthcare NHSTrust Torquay UK TQ2 7AA Phone: 00-44-7886080203Email: [email protected] References1. Hart R, Janeck M, Bucek B. Case report of extensivemetallosis in extra articular tissues after unicompartmentalknee joint replacement. Acta Chir Orthop Traumatol Cech.2003; 70(1): 47-50.2. McGovern TF, Moskal JT. Radiographic evaluation ofperiprosthetic metallosis after total knee replacement. JSouth Orthop Assoc. 2002 Spring; 11(1):18-24.3. Worland RL, Arrendondo J, Angles F, Jessup DE.Scintigraphic evaluation in total knee failure secondary tosevere metallosis. J Arthroplasty. 1998 Jan; 13(1):116-9.4. Della Valle CJ, Bogner E, Desai P, Lonner JH, Adler E,Zuckerman JD, Di Cesare PE. Analysis of frozen sections ofintraoperative specimens obtained at the time of reoperationafter hip or knee resection arthroplasty for the treatment ofinfection. J Bone Joint Surg Am. 1999 May; 81(5):684-9. Metallosis in an apparently well fixed total knee replacement 3 of 3Author InformationPavel Mukherjee, MRCSDepartment of Orthopaedic Surgery, South Devon Healthcare NHS Trust, Torbay Hospital Mark J. Ashworth, FRCS (Orth)Department of Orthopaedic Surgery, South Devon Healthcare NHS Trust, Torbay Hospital

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallosis Presenting as Knee Pain 26 years after Primary Total Knee Arthroplasty

INTRODUCTION Metallosis occurs when periprosthetic soft tissues, synovium, and/or bone is infiltrated by metallic debris secondary to metal-on-metal wear. This debris can cause a chronic inflammatory reaction leading to joint instability, pain, and swelling, and may cause osteolysis, implant looseningand ultimately implant failure. CASE REPORT An 81 year old female, with a history of primary ...

متن کامل

Apparent Skin Discoloration about the Knee Joint: A Rare Sequela of Metallosis after Total Knee Replacement

Introduction. Metallosis is a phenomenon most commonly associated with hip replacement. However it can occur in any metallic implant subject to wear. Wear creates metal debris, which is deposited in the surrounding soft tissue. This leads to many local adverse reactions including, but not limited to, implant loosening/osteolysis, pain, and effusion. In the deeper joints, for example, the hip, m...

متن کامل

Wear debris pseudotumor following total knee arthroplasty: a case report

INTRODUCTION In patients who have undergone a total joint replacement, any mass occurring in or adjacent to the joint needs thorough investigation and a wear debris-induced cyst should be suspected. CASE PRESENTATION An 81-year-old man presented with a painful and enlarging mass at the popliteal fossa and calf of his right knee. He had had a total right knee replacement seven years previously...

متن کامل

A Report of 15 Cases

J Bone Joint Surg [Br] 2011;93-B:205-9. Received 5 May 2010; Accepted after revision 12 October 2010 Metallosis is a rare cause of failure after total knee replacement and has only previously been reported when there has been abnormal metal-on-metal contact. We describe 14 patients (15 knees) whose total knee replacement required revision for a new type of early failure caused by extensive meta...

متن کامل

Metallosis and Metal-Induced Synovitis Following Total Knee Arthroplasty: Review of Radiographic and CT Findings.

Metallosis and metal-induced synovitis are well-recognized complications of metal-backed polyethylene joint prostheses and have been frequently described in the orthopedic surgery literature; however, relatively fewer articles discussing the radiologic aspects of this complication have been published. To illustrate the importance of radiologic findings in the diagnosis and management of these p...

متن کامل