Intracranial pressure monitoring.

نویسندگان

  • R Stefini
  • F A Rasulo
چکیده

Recent studies have demonstrated that bedside cranial burr hole and insertion of intraparenchymal catheters for intracranial pressure monitoring performed by intensive care physicians is a safe procedure, with a complication rate comparable to other series published by neurosurgeons. The overall morbidity rate is comparable to, or even lower than, that caused by central vein catheterization. The procedure is also quite simple and modern disposable intracranial procedural kits are available. After the skin is prepped the landmark for skin incision, called the 'Kocher's point', located about 2-4 cm lateral to the midline (mid-pupillary line) and 2-3 cm anterior to the coronal suture, is found. Then the surgical field is prepared with the sterile drapes and the skin infiltrated with local anaesthetic (0.5% lidocaine with 1 : 200000 epinephrine). After skin incision and retraction of the skin and subcutaneous tissue, the periosteum should be scraped off in order expose the skull. The skin is then divaricated, exposing the underlying bone. The hole is drilled with either an electric drill or a twist drill (the drilling procedure must be performed with the drill held within 10 degrees of the perpendicular position to the incision site). The hole is then irrigated with sterile saline and an 18-G spinal needle may be used to open the dura (exercise caution when perforating the dura so as to avoid damage to the underlying structures). Following opening of the dura, the Bolt, containing a stylet, is screwed manually into the skull at approximately 5 mm to 1 cm for adults. The stylet is then removed after the bolt has been screwed in, after which the bolt should be filled with saline. Finally, the zeroing of the transducer is performed by simply holding the tip in air while zeroing on the monitor. The transducer is inserted inside the bolt and the screw tightened. The intracranial pressure value can then be read.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Colombian-based survey on ventriculostomy and intracranial pressure monitor placement practices

Objective: Monitoring of intracranial pressure (ICP) is a routine procedure in the neurosurgery field. Although the routine practice of monitoring ICP has decreased in recent years, the practice patterns have not been studied in Colombia. This study was designed to evaluate the current practice forventriculostomy and ICP monitoring by neurosurgeons in Colombia. Methods...

متن کامل

Prognostic significance of intracranial pressure monitoring and intracranial hypertension in severe brain trauma patients.

Since without prospective randomized studies it is not possible to have a clear attitude towards the importance of intracranial pressure monitoring, this study was aimed at examining the prognostic effect of the intracranial pressure monitoring and intracranial pressure oriented therapy in severe brain trauma patients, and at defining optimal intracranial pressure values for starting the treatm...

متن کامل

Novel methods to predict increased intracranial pressure during intensive care and long-term neurologic outcome after traumatic brain injury: development and validation in a multicenter dataset.

OBJECTIVE Intracranial pressure monitoring is standard of care after severe traumatic brain injury. Episodes of increased intracranial pressure are secondary injuries associated with poor outcome. We developed a model to predict increased intracranial pressure episodes 30 mins in advance, by using the dynamic characteristics of continuous intracranial pressure and mean arterial pressure monitor...

متن کامل

Intracranial pressure monitoring: Vital information ignored

Free full text available from www.ijccm.org A b st ra ct Though there is no Class I evidence for the benefit of intracranial pressure (ICP) monitoring, the bulk of the published literature supports its use when indicated. This review deals with the pathophysiology of raised ICP, evidence for and against monitoring, and basic guidelines for monitoring. It is unfortunate that ICP monitoring is no...

متن کامل

اندازه‌گیری فشار داخل جمجمه در بیماران دچار صدمات تروماتیک مغزی در بیمارستان باهنر کرمان: یک گزارش کوتاه

Background and Objective: Although intracranial pressure (ICP) monitoring is considered as the standard care for traumatic brain injuries, it is not routinely used in Iran. Hence, the purpose of this study is to reveal the primary results of the applying ICP monitoring in patients with traumatic head injuries in Bahonar Hospital in Kerman. Materials and Methods:The present study is a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of anaesthesiology. Supplement

دوره 42  شماره 

صفحات  -

تاریخ انتشار 1984