Comparison of Aerosol Formulations of Formoterol Fumarate and Budesonide

نویسندگان

  • N. M. Nirale
  • M. S. Nagarsenker
  • S. B. Mendon
  • R. Chanagare
  • A. Katkurwar
  • V. Lugade
چکیده

The aerodynamic diameter of pharmaceutical aerosols is the main factor governing their deposition in the human respiratory tract. Particle size of the pharmaceutical aerosols is characterized by liquid impingers and Andersen Cascade Impactors. The present study was aimed at comparing two metered dose inhaler formulation containing formoterol fumarate (6 μg) and budesonide (200 μg). These two formulations were evaluated by using Twin Stage Impinger and Andersen Cascade Impactor. Study revealed that developed metered dose inhaler I formulation of the formoterol fumarate and budesonide had lower mass median aerodynamic diameter and higher fine particle fraction than marketed formulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Equivalent Lung Dose and Systemic Exposure of Budesonide/Formoterol Combination via Easyhaler and Turbuhaler

BACKGROUND Easyhaler(®) device-metered dry powder inhaler containing budesonide and formoterol fumarate dihydrate (hereafter formoterol) for the treatment of asthma and chronic obstructive pulmonary disease has been developed. The current approvals of the product in Europe were based on several pharmacokinetic (PK) bioequivalence (BE) studies, and in vitro-in vivo correlation (IVIVC) modeling. ...

متن کامل

Pharmaceutical equivalence of the combination formulation of budesonide and formoterol in a single capsule with a dry powder inhaler.

OBJECTIVE To evaluate the pharmaceutical equivalence of a test formulation (fixed-dose combination of budesonide and formoterol fumarate in a single capsule dispensed in an Aerocaps® inhaler) in relation to a reference formulation (budesonide and formoterol fumarate in two separate capsules dispensed in an Aerolizer® inhaler). METHODS This was an in vitro study in which we performed the ident...

متن کامل

Fluticasone/formoterol combination therapy versus budesonide/formoterol for the treatment of asthma: a randomized, controlled, non-inferiority trial of efficacy and safety.

OBJECTIVES The inhaled corticosteroid fluticasone propionate (fluticasone) and the long-acting β₂ agonist formoterol fumarate (formoterol) have been combined in a single aerosol inhaler fluticasone/formoterol (flutiform(®)). This study compared the efficacy and safety of fluticasone/formoterol with the combination product budesonide/formoterol (Symbicort(®) Turbohaler(®)). METHODS A randomize...

متن کامل

Effect of Flow Rate on In Vitro Aerodynamic Performance of NEXThaler® in Comparison with Diskus® and Turbohaler® Dry Powder Inhalers

BACKGROUND European and United States Pharmacopoeia compendial procedures for assessing the in vitro emitted dose and aerodynamic size distribution of a dry powder inhaler require that 4.0 L of air at a pressure drop of 4 kPa be drawn through the inhaler. However, the product performance should be investigated using conditions more representative of what is achievable by the patient population....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 73  شماره 

صفحات  -

تاریخ انتشار 2011