Halo size under distance and near conditions in refractive multifocal intraocular lenses.
نویسندگان
چکیده
AIMS To calculate the diameter of halos perceived by patients with multifocal intraocular lenses (IOLs) and to stimulate halos in patients with refractive multifocal IOLs in a clinical experiment. METHODS Calculations were done to show the diameter of halos in the case of the bifocal intraocular lens. 24 patients with a refractive multifocal IOLs and five patients with a monofocal IOL were asked about their subjective observation of halos and were included in a clinical experiment using a computer program (Glare & Halo, FW Fitzke and C Lohmann, Tomey AG) which simulates a light source of 0.15 square degrees (sq deg) in order to stimulate and measure halos. Halo testing took place monoculary, under mesopic conditions through the distance and the near focus of the multifocal lens and through the focus of the monofocal lens. RESULTS The halo diameter depends on the pupil diameter, the refractive power of the cornea, and distance focus of the multifocal IOL as well as the additional lens power for the near focus. 23 out of 24 patients with a refractive multifocal IOL described halos at night when looking at a bright light source. Only one patient was disturbed by the appearance of halos. Under test conditions, halos were detected in all patients with a refractive multifocal IOL. The halo area testing through the distance focus was 1.05 sq deg +/- 0.41, through the near focus 1.07 sq deg +/- 0.49 and in the monofocal lens 0.26 sq deg +/- 0.13. CONCLUSIONS Under high contrast conditions halos can be stimulated in all patients with multifocal intraocular lenses. The halo size using the distance or the near focus is identical.
منابع مشابه
Tritan colour contrast sensitivity function in refractive multifocal intraocular lenses.
AIMS To compare tritan colour contrast sensitivity (CCS), without and with glare, in patients with refractive multifocal intraocular lenses (IOLs) and with monofocal intraocular lenses. METHODS Tritan CCS was determined (Moorfields Vision System, CH Electronics) in 15 eyes (14 patients, 75.7 (+/-6.6) years) with a refractive multifocal IOL (Allergan SA 40N) and in 11 eyes (10 patients, 73.7 (...
متن کاملVisual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison.
AIM To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). METHODS Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular...
متن کاملPiggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.
PURPOSE To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to corr...
متن کاملComparison of outcomes with multifocal intraocular lenses: a meta-analysis
PURPOSE To compare the clinical outcome of different multifocal intraocular lenses (IOLs) based on information reported in the international literature. METHODS All comparative clinical trials that involved implanting at least one multifocal IOL in patients with cataract or presbyopia were extracted from the literature. Clinical outcomes included uncorrected near visual acuity, uncorrected di...
متن کاملHalo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses.
PURPOSE To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 85 7 شماره
صفحات -
تاریخ انتشار 2001