New electrocardiographic criteria for the differentiation between counterclockwise and clockwise atrial flutter: correlation with electrophysiological study and radiofrequency catheter ablation.

نویسندگان

  • L P Lai
  • J L Lin
  • L J Lin
  • W J Chen
  • Y L Ho
  • Y Z Tseng
  • C H Chen
  • Y T Lee
  • W P Lien
  • S K Huang
چکیده

OBJECTIVE To develop new electrocardiographic (ECG) criteria for the differentiation between counterclockwise and clockwise atrial flutters. BACKGROUND Traditionally, the ECG differentiation between counterclockwise and clockwise atrial flutters is based on the flutter wave polarity in the inferior leads. However, determination of flutter wave polarity is subjective and sometimes difficult, especially in flutter waves of undulating pattern. PATIENTS The study comprised 37 consecutive patients with drug resistant atrial flutter; 30 had counterclockwise and 17 had clockwise atrial flutter (10 had both forms of atrial flutter). The isthmus dependence was confirmed by entrainment study and catheter ablation. The ECG patterns of both types of atrial flutter were compared and the flutter wave polarity in the inferior leads was determined by four independent cardiologists. RESULTS The flutter wave polarity in the inferior leads appeared negative in 24, positive in one, and equivocal in five of the counterclockwise atrial flutters; polarity appeared negative in one, positive in 10, and equivocal in six of the clockwise atrial flutters. However, the aVF/lead I flutter wave amplitude ratio was > 2.5 in all counterclockwise but < 2.5 in all clockwise atrial flutters. The flutter wave nadirs in the inferior leads corresponded to the upstrokes in V1 in all counterclockwise atrial flutters, but corresponded to the downstrokes in V1 in all clockwise atrial flutters. CONCLUSIONS The flutter wave polarity in the inferior leads does not correlate well with the flutter wave rotating direction. However, counterclockwise and clockwise atrial flutters can be differentiated by new ECG criteria with high accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A classification of atrial flutter and regular atrial tachycardia according to electrophysiological mechanisms and anatomical bases. A Statement from a Joint Expert Group from the Working Group of Arrhythmias of the European Society of Cardiology and the

Current classifications of regular atrial tachycardias have been based exclusively on the ECG. Differentiation between atrial flutter and atrial tachycardia depends on a rate cut-off around 240–250/min and the presence of isoelectric baselines between atrial deflections in atrial tachycardia, but not in atrial flutter. However, atrial tachycardia mechanisms, defined by electrophysiological stud...

متن کامل

Partial cavotricuspid isthmus block before ablation in patients with typical atrial flutter.

OBJECTIVES The purpose of this study was to prospectively evaluate preexisting partial isthmus block in the context of an electrophysiologically directed linear ablation strategy for typical atrial flutter (AF). BACKGROUND Double potentials (DPs) separated by an isoelectric interval have been recognized as markers of local block. However, the presence and significance of DPs in the cavotricus...

متن کامل

Atrial tachycardia arising from the right atrial inferoseptum masquerading as common atrial flutter.

Radiofrequency catheter ablation was performed in 2 patients with atrial tachycardia (AT). In both cases the AT originated from the inferoseptal portion of the right atrium, and the cycle length was 210 ms. The surface ECG demonstrated common counterclockwise atrial flutter, probably caused by functional block in the clockwise direction at the cavo-tricuspid isthmus and posterior right atrium w...

متن کامل

Electrophysiological determinant for induction of isthmus dependent counterclockwise and clockwise atrial flutter in humans.

OBJECTIVE To investigate the electrophysiological determinant underlying the electrical induction of counterclockwise and clockwise isthmus dependent atrial flutter. PATIENTS AND METHODS The isthmus bordered by the inferior vena caval orifice-tricuspid annulus-coronary sinus ostium (IVCO-TA-CSO) has been assumed to be the site of both slow conduction and unidirectional block critical to the i...

متن کامل

Single-catheter validation of bidirectional block during atrial flutter ablation

Introduction Radiofrequency catheter ablation (RFCA) of typical atrial flutter (AFL) is an effective and widely performed method of treatment. Confirmation of conduction block in the cavotricuspid isthmus (CTI) is the best endpoint of the procedure. Electrophysiological measurements for validation of CTI block are usually performed using 2 or 3 catheters. However, in some situations this multi-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 1998