New Radiofrequency Device to Reduce Bleeding after Core Needle Biopsy: Experimental Study in a Porcine Liver Model

نویسندگان

  • Sanghyeok Lim
  • Hyunchul Rhim
  • Min Woo Lee
  • Kyoung Doo Song
  • Tae Wook Kang
  • Young-sun Kim
  • Hyo Keun Lim
چکیده

OBJECTIVE To evaluate the in vivo efficiency of the biopsy tract radiofrequency ablation for hemostasis after core biopsy of the liver in a porcine liver model, including situations with bleeding tendency and a larger (16-gauge) core needle. MATERIALS AND METHODS A preliminary study was performed using one pig to determine optimal ablation parameters. For the main experiment, four pigs were assigned to different groups according to heparinization use and biopsy needle caliber. In each pig, 14 control (without tract ablation) and 14 experimental (tract ablation) ultrasound-guided core biopsies were performed using either an 18- or 16-gauge needle. Post-biopsy bleeding amounts were measured by soaking up the blood for five minutes. The results were compared using the Mann-Whitney U test. RESULTS The optimal parameters for biopsy tract ablation were determined as a 2-cm active tip electrode set at 40-watt with a tip temperature of 70-80℃. The bleeding amounts in all experimental groups were smaller than those in the controls; however they were significant in the non-heparinized pig biopsied with an 18-gauge needle and in two heparinized pigs (p < 0.001). In the heparinized pigs, the mean blood loss in the experimental group was 3.5% and 13.5% of the controls biopsied with an 18- and 16-gauge needle, respectively. CONCLUSION Radiofrequency ablation of hepatic core biopsy tract ablation may reduce post-biopsy bleeding even under bleeding tendency and using a larger core needle, according to the result from in vivo porcine model experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiofrequency cauterization with biopsy introducer needle.

PURPOSE The principal risks of needle biopsy are hemorrhage and implantation of tumor cells in the needle tract. This study compared hemorrhage after liver and kidney biopsy with and without radiofrequency (RF) ablation of the needle tract. MATERIALS AND METHODS Biopsies of liver and kidney were performed in swine through introducer needles modified to allow RF ablation with the distal 2 cm o...

متن کامل

Emergency laparoscopy combined with radiofrequency ablation for hemostasis after percutaneous liver biopsy.

There are no data in the literature on the use of radiofrequency ablation (RFA) in emergency laparoscopy as a means of hemostasis after liver biopsy. In this case report we have described a case of a patient with Waldenstrom macroglobulinemia and hypervascularised hepatic tumor who developed severe hepatic bleeding after liver biopsy. Innovative, minimally invasive treatment consisted in a lapa...

متن کامل

Advancement in liver laparoscopic resection – development of a new surgical device

Liver resection is the standard treatment for any liver lesion. Laparoscopic liver resection is associated with lower intra-operative blood loss and fewer complications than open resection. Access to the posterior part of the right liver lobe is very uncomfortable and difficult for surgeons due the anatomic position, especially when employing laparoscopic surgery. Based on these experiences, a ...

متن کامل

مقایسه اثر کلسیم سولفات و کلرید فریک در کنترل خونریزی طی جراحی کبدی؛ مطالعه مدل حیوانی

Background and Objective: The control of parenchymal hemorrhage especially in liver parenchyma, despite improvements in surgical science, is still one of the challenges that surgeons are facing with. Therefore, introducing an effective method to control liver bleeding is of important research priority. This study aimed to compare the hemostatic effect of calcium sulfate and ferric chloride on c...

متن کامل

Assessment of Factors Affecting the Usefulness and Diagnostic Yield of Core Biopsy Needles with a Side Hole in Endoscopic Ultrasound-Guided Fine-Needle Aspiration

BACKGROUND/AIMS A barbed puncture needle with a side hole was recently developed to improve sample quality and quantity in endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). In this study, we retrospectively assessed the usefulness of this puncture needle. METHODS Factors affecting diagnostic yield, safety, and diagnostic accuracy were investigated in 76 patients who consecutively...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017