New evidence for large negative xylem pressures and their measurement by the pressure chamber method

نویسندگان

  • J. S. SPERRY
  • N. Z. SALIENDRA
  • W. T. POCKMAN
  • H. COCHARD
  • P. CRUIZIAT
  • S. D. DAVIS
  • F. W. EWERS
  • M. T. TYREE
چکیده

Pressure probe measurements have been interpreted as showing that xylem pressures below c. -0-4MPa do not exist and that pressure chamber measurements of lower negative pressures are invalid. We present new evidence supporting the pressure chamber technique and the existence of xylem pressures well below -0-4 MPa. We deduced xylem pressures in water-stressed stem xylem from the following experiment: (1) loss of hydraulic conductivity in hydrated stem xylem (xylem pressure = atmospheric pressure) was induced by forcing compressed air into intact xylem conduits; (2) loss of hydraulic conductivity from cavitation and embolism in dehydrating stems was measured, and (3) the xylem pressure in dehydrated stems was deduced as being equal and opposite to the air pressure causing the same loss of hydraulic conductivity in hydrated stems. Pressures determined in this way are only valid if cavitation was caused by air entering the xylem conduits (air-seeding). Deduced xylem pressure showed a one-to-one correspondence with pressure chamber measurements for 12 species (woody angiosperms and gymnosperms); data extended to c. -10 MPa. The same correspondence was obtained under field conditions in Betula occidentalis Hook., where pressure differences between airand water-filled conduits were induced by a combination of in situ xylem water pressure and applied positive air pressure. It is difficult to explain these results if xylem pressures were above —0-4MPa, if tbe pressure chamber was inaccurate, and if cavitation occurred by some mechanism other than air-seeding. A probable reason why the pressure probe does not register large negative pressures is tbat, just as cavitation witbin the probe limits its calibration to pressures above c. —0-5 MPa, cavitation limits its measurement range

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of centrifugal force in the study of xylem cavitation

Two methods were evaluated for using centrifugal force to measure the occurrence of cavitation as a function of negative pressures in xylem. The general protocol was to measure the hydraulic conductivity of xylem segments (stem or root pieces) before and after centring them on a centrifuge rotor and spinning them about their long axis to generate negative xylem pressure. The percentage decrease...

متن کامل

Introducing of the propagation criterion and investigation of that for near vacuum chamber pressures for multi hole gasoline direct injector spray

with developing of optical technologies, using of different imaging methods to study various properties of gasoline direct injection spray is under development. Scope of this article is  to study the effect of overall spray angle and spray projected area for determination of spray propagation and investigate the effectiveness of this criterion.  The injector was a multi-hole direct injection in...

متن کامل

Use of positive pressures to establish vulnerability curves : further support for the air-seeding hypothesis and implications for pressure-volume analysis.

Loss of hydraulic conductivity occurs in stems when the water in xylem conduits is subjected to sufficiently negative pressure. According to the air-seeding hypothesis, this loss of conductivity occurs when air bubbles are sucked into water-filled conduits through micropores adjacent to air spaces in the stem. Results in this study showed that loss of hydraulic conductivity occurred in stem seg...

متن کامل

Xylem resistance to embolism: presenting a simple diagnostic test for the open vessel artefact.

Xylem vulnerability to embolism represents an essential trait for the evaluation of the impact of hydraulics in plant function and ecology. The standard centrifuge technique is widely used for the construction of vulnerability curves, although its accuracy when applied to species with long vessels remains under debate. We developed a simple diagnostic test to determine whether the open-vessel a...

متن کامل

Measurement of the water potential of stored potato tubers.

A method of measuring the water potential of stored potato tubers (Solanum tuberosum L.) was needed to investigate the relationship of bacterial soft rot in tubers to water potential. Pressure chamber measurements, while useful for tubers with functional stolons, cannot be made on stored tubers. Measurements could be made on excised tissue pieces in a hygrometer chamber and with hygrometers imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005