Analysis of ethanol in expired air during low-flow isoflurane anaesthesia.

نویسندگان

  • J Olsson
  • R G Hahn
چکیده

Monitoring of ethanol concentration in expired air is a method for assessing fluid absorption during transurethral prostatic surgery and endometrial resection, but the validity of this technique has not been studied in low-flow ventilation systems. For this purpose, we have compared the concentration-time profiles of ethanol in expired gas and in venous blood during an i.v. infusion of 0.4 g kg-1 of ethanol over 30 min in 10 women during isoflurane anaesthesia and in the awake state. Anaesthesia increased the ethanol concentration in expired gas by 13% and in venous blood by 34%. The expired gas-blood difference during infusion was abolished, and the central volume of distribution for ethanol was reduced from 20.9 to 8.6 litre, on average. We conclude that breath sampling during low-flow isoflurane anaesthesia reflects an alcohol load well, but that a change in ethanol disposition makes the values slightly higher than in the awake state.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of desflurane and isoflurane on splanchnic microcirculation during major surgery.

Isoflurane has been considered the agent of choice where preservation of splanchnic blood flow is required. Liver blood flow and the hepatic artery buffer response are maintained better in the presence of isoflurane than with other volatile anaesthetic agents. The effects of desflurane have not been assessed in humans. Therefore, we have compared the effects of isoflurane and desflurane anaesth...

متن کامل

Fuzzy logic control of inspired isoflurane and oxygen concentrations using minimal flow anaesthesia.

In order to evaluate the performance of feedback fuzzy logic control of inspired oxygen and isoflurane concentrations, we studied 30 patients undergoing discectomy for lumbar (n = 26) or cervical (n = 4) disc herniation. Patients were allocated random to one of two groups: a standard group (n = 15) with low flow anaesthesia (1.2-1.3 litre min-1) and manual control of gas concentrations; and a f...

متن کامل

Model-based administration of inhalation anaesthesia. 4. Applying the system model.

BACKGROUND We developed and tested a simple dosing strategy for rapid induction with isoflurane followed by maintenance under minimal-flow conditions, that is 0.5 litre min(-1) total fresh gas flow (FGF). An end-expired concentration was to be achieved within 5 min in a desired therapeutic window, that is 0.8-1.1 vol%, and to be maintained within it for at least 30 min. METHODS With our new m...

متن کامل

Anaesthetic uptake and elimination: is there a difference between halothane and isoflurane in the dog?

In two groups of dogs, the uptake and elimination of halothane and isoflurane were studied using a closed-loop anaesthetic system which automatically controlled end-tidal halothane and isoflurane partial pressures at equi-MAC concentrations. Haemodynamic and respiratory variables were recorded and the anaesthetic partial pressures were measured in the inspired and expired air, as well as in the...

متن کامل

A technique for evaluating expired air mixing devices.

A simple method for measuring the efficiency of expired air mixing devices is described. Preliminary studies comparing a number of mixing chambers indicate that the bag-inbottle system is the most efficient. The dependence of mixing efficiency on VT, f and expired flow rate is demonstrated. Two types of mixing failure are distinguished. The clinical implications are discussed, including those r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 76 1  شماره 

صفحات  -

تاریخ انتشار 1996