Local in vivo shimming using adaptive passive shim positioning.

نویسندگان

  • Sejung Yang
  • Hahnsung Kim
  • Min-Oh Ghim
  • Byung-Uk Lee
  • Dong-Hyun Kim
چکیده

A subject-specific local in vivo passive shimming method, focusing on the prefrontal and temporal regions, is proposed. The aim of the investigation is to show that subject variability exists in optimal passive shimming and that the proposed method can be effectively used to overcome these differences. A shimming structure capable of adjusting the position of the passive shims to within a millimeter resolution is built. The optimal shim positions for each individual subject are computed from obtained field map using a convex optimization algorithm. Passive shim experiments at predetermined fixed shim positions vs. individually adjusted shim positions were performed and compared. The results show that intersubject variability exists in the optimal shim positions and that the location-sensitive method proposed can be useful for improving main field homogeneity in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simple Approach of Combined Passive and Active Shimming for In Vivo MR Spectroscopy at High Magnetic Field

High magnetic fields increase the sensitivity and spectral dispersion in MR spectroscopy. However, spectral peaks are broadened in vivo at higher field strength due to stronger susceptibility-induced effects. Strategies to minimize the spectral linewidth by optimal shimming are therefore of critical importance. In our current 7T MR system, the shim requirements exceeded the dynamic range of the...

متن کامل

Comparison of Volume-Selective z-Shim and EPI with an fMRI Memory Task

shimming > epi; right: epi > z-shimming. P < 0.05 uncorrected. Fig. 2. Activation map from 6 subjects using z-shimming (left) and normal EPI (right). P < 0.01 uncorrected. Fig. 1. schematic drawing of the volume selective z-shimming slices. Solid lines: actual slices for imaging; solid red lines: slices to apply z-shim; dashed red lines: virtual slices during slice positioning, the actual slice...

متن کامل

Simple approach of combined passive and active shimming for in vivo MR spectroscopy of the brain

High magnetic fields increase the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS). In contrast, spectral peaks are broadened in vivo at higher field strength due to stronger susceptibility-induced effects. Strategies to minimize the spectral linewidth by optimal shimming are therefore of critical importance. The problem of shim requirements exceeding the active shim...

متن کامل

Reducing image artefacts in concurrent TMS/fMRI by passive shimming

A significant problem in the concurrent application of transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) is the image artefact caused by the effect of the TMS-coil on the homogeneity of the static magnetic field (B0). The resulting field inhomogeneity can lead to spatial distortions and local signal loss in echo-planar (EP) images. Here we demonstrate that...

متن کامل

The effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T

BACKGROUND Dual-channel transmit technology improves the image quality in cardiovascular magnetic resonance (CMR) at 3 T by reducing the degree of radiofrequency (RF) shading over the heart by using RF shimming. Further improvements in image quality have been shown on a dual-transmit system using high permittivity pads. The aim of this study is to investigate the transmit field (B 1 (+)) homoge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 2011