Smithsonian Astrophysical Observatory Ozone Mapping and Profiler Suite (SAO OMPS) formaldehyde retrieval
نویسندگان
چکیده
This paper presents our new formaldehyde (H2CO) retrievals, obtained from spectra recorded by the nadir instrument of the Ozone Mapping and Profiler Suite (OMPS) flown on board NASA’s Suomi National Polarorbiting Partnership (SUOMI-NPP) satellite. Our algorithm is similar to the one currently in place for the production of NASA’s Ozone Monitoring Instrument (OMI) operational H2CO product. We are now able to produce a set of longterm data from two different instruments that share a similar concept and a similar retrieval approach. The ongoing overlap period between OMI and OMPS offers a perfect opportunity to study the consistency between both data sets. The different spatial and spectral resolution of the instruments is a source of discrepancy in the retrievals despite the similarity of the physic assumptions of the algorithm. We have concluded that the reduced spectral resolution of OMPS in comparison with OMI is not a significant obstacle in obtaining good-quality retrievals. Indeed, the improved signal-to-noise ratio of OMPS with respect to OMI helps to reduce the noise of the retrievals performed using OMPS spectra. However, the size of OMPS spatial pixels imposes a limitation in the capability to distinguish particular features of H2CO that are discernible with OMI. With root mean square (RMS) residuals∼ 5×10−4 for individual pixels we estimate the detection limit to be about 7.5× 1015 moleculescm−2. Total vertical column density (VCD) errors for individual pixels range between 40 % for pixels with high concentrations to 100 % or more for pixels with concentrations at or below the detection limit. We compare different OMI products (SAO OMI v3.0.2 and BIRA OMI v14) with our OMPS product using 1 year of data, between September 2012 and September 2013. The seasonality of the retrieved slant columns is captured similarly by all products but there are discrepancies in the values of the VCDs. The mean biases among the two OMI products and our OMPS product are 23 % between OMI SAO and OMPS SAO and 28 % between OMI BIRA and OMPS SAO for eight selected regions.
منابع مشابه
First results from a rotational Raman scattering cloud algorithm applied to the Suomi National Polar-orbiting Partnership (NPP) Ozone Mapping and Profiler Suite (OMPS) Nadir Mapper
This paper reports initial results from an Ozone Mapping and Profiler Suite (OMPS) Nadir Mapper cloud pressure and cloud fraction algorithm. The OMPS cloud products are intended for use in OMPS ozone or other tracegas algorithms. We developed the OMPS cloud products using a heritage algorithm developed for the Ozone Monitoring Instrument (OMI) on NASA’s Aura satellite. The cloud pressure algori...
متن کاملMeasuring the Antarctic ozone hole with the new Ozone Mapping and Profiler Suite (OMPS)
The new Ozone Mapping and Profiler Suite (OMPS), which launched on the Suomi National Polarorbiting Partnership satellite in October 2011, gives a detailed view of the development of the Antarctic ozone hole and extends the long series of satellite ozone measurements that go back to the early 1970s. OMPS includes two modules – nadir and limb – to measure profile and total ozone concentrations. ...
متن کاملA new algorithm for detecting cloud height using OMPS/LP measurements
The Ozone Mapping and Profiler Suite Limb Profiler (OMPS/LP) ozone product requires the determination of cloud height for each event to establish the lower boundary of the profile for the retrieval algorithm. We have created a revised cloud detection algorithm for LP measurements that uses the spectral dependence of the vertical gradient in radiance between two wavelengths in the visible and ne...
متن کاملAn Overview of the Nadir Sensor and Algorithms for the NPOESS Ozone Mapping and Profiler Suite (OMPS)
The Ozone Mapping and Profiler Suite (OMPS) nadir sensor and algorithms for the United States National Polarorbiting Operational Environmental Satellite System (NPOESS) comprise a system to map ozone total column globally in 24 hours and to measure the altitude distribution of ozone in the upper stratosphere (30-50 km). The sensor consists of a wide field (110 degree) telescope and two spectrom...
متن کاملPostlaunch performance of the Suomi National Polarorbiting Partnership Ozone Mapping and Profiler Suite (OMPS) nadir sensors
The prelaunch specifications for nadir sensors of the Ozone Mapping and Profiler Suite (OMPS) were designed to ensure that measurements from them could be used to retrieve total column ozone and nadir ozone profile information both for operational use and for use in long-term ozone data records. In this paper, we will show results from our extensive analysis of the performance of the nadir mapp...
متن کامل