Identification Faults on Transmission Line by using Phasor Measurement Unit (PMUs)
نویسندگان
چکیده
The phenomenal growth of power system network both in terms of geographical sprawl as well as technological advancements, it requires tools for dealing with the system, wide disturbances that often cause widespread catastrophic blackouts in power system networks. When a major disturbance occurs, protection and control measures play the most important role to prevent further degradation of the system, to restore the system back to a normal state and minimize the impact of the disturbance. Continuous technological innovations in information and communication technology, novel sensors and measurement principles in general have promoted the advent of Phasor Measurement Units (PMUs). This paper describes the modelling and testing of Phasor Measurement Unit for two bus transmission line system for identification faults(like LG fault) using MATLAB/Simulink. Since PMUs are costly device therefore module wise testing and analysis are essential. For such modelling and testing, software based analysis is the best approach. This has been done through MATLAB and the results were analysed.
منابع مشابه
Optimal Placement of Phasor Measurement Units to Maintain CompleteObservability Considering Maximum Reliability by Non-dominated Sorting Genetic Algorithm-II (NSGA-II)
Ever-increasing energy demand has led to geographic expansion of transmission lines and their complexity. In addition, higher reliability is expected in the transmission systemsdue to their vital role in power systems. It is very difficult to realize this goal by conventional monitoring and control methods. Thus, phasor measurement units (PMUs) are used to measure system parameters. Although in...
متن کاملPresenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units
In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...
متن کاملOptimal Placement of Phasor Measurement Units in Khorasan Network Using a Hybrid Intelligent Technique
In this paper, an efficient and comprehensive hybrid intelligent technique for the optimal placement of phasor measurement units (PMUs) is proposed to minimize the number of PMU installation subjected to full network observability. Three main purposes of PMUs output synchronous measurements are monitoring, control, and protection of power system. We have combined Binary Imperialistic Competitio...
متن کاملSimplified procedure to estimate the resistance parameters of transmission lines
An alternative and simplified procedure is described to estimate the longitudinal resistances of transmission lines based on the real-time load profile. This method proposes to estimate the resistance parameters from the synchronized measurements of complex currents and complex voltages at the sending and receiving ends of transmission systems. The synchronized measurements can be in practice o...
متن کاملAn adaptive distance protection scheme in the presence of phase shifting transformer
Distance relays detect transmission line faults and their locations by measuring the voltage and the current signals. Also, phase shifting transformers (PSTs) are used to control the power flow in electrical power systems. PSTs protect transmission lines from thermal overloading, improve the stability of transmission system and control the power flow between different networks. Unfortunately, e...
متن کامل