Calibration of a monochromator using a lambdameter

نویسندگان

  • T. Schwarzmaier
  • A. Baumgartner
  • P. Gege
  • K. Lenhard
چکیده

The standard procedure for wavelength calibration of monochromators in the visible and near infrared wavelength range uses low-pressure gas discharge lamps with spectrally well-known emission lines as primary wavelength standard. The calibration of a monochromator in the wavelength range of 350 to 2500 nm usually takes some days due to the huge number of single measurements necessary. The useable emission lines are not for all purposes sufficiently dense and at the appropriate wavelengths. To get faster results for freely selectable wavelengths, a new method for monochromator characterization was tested. It is based on measurements with a lambdameter taken at equidistant angles distributed over the grating's entire angular range. This method provides a very accurate calibration and needs only about two hours of measuring time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The calibration of scanning monochromators for the measurement of absolute irradiance.

Certain approximations commonly used in the absolute calibration of a scanning monochromator are examined in terms of the response of the instrument to a monochromatic input. The absolute irradiance due to any spectral feature in the neighborhood of lambda(0) is commonly computed from the expression W = AB(lambda(0))/H(lambda(0)) where A is the area of the spectral feature as recorded by the mo...

متن کامل

Ultra-stable sub-meV monochromator for hard X-rays

A high-resolution silicon monochromator suitable for 21.541 keV synchrotron radiation is presented that produces a bandwidth of 0.27 meV. The operating energy corresponds to a nuclear transition in (151)Eu. The first-of-its-kind, fully cryogenic design achieves an energy-alignment stability of 0.017 meV r.m.s. per day, or a 100-fold improvement over other meV-monochromators, and can tolerate hi...

متن کامل

Optimized Spectrometers Characterization Procedure for Near Ground Support of ESA FLEX Observations: Part 1 Spectral Calibration and Characterisation

The paper presents two procedures for the wavelength calibration, in the oxygen telluric absorption spectral bands (O2-A, λc = 687 nm and O2-B, λc = 760.6 nm), of field fixed-point spectrometers used for reflectance and Sun-induced fluorescence measurements. In the first case, Ne and Ar pen-type spectral lamps were employed, while the second approach is based on a double monochromator setup. Th...

متن کامل

Methods for spectral characterization of multispectral cameras

High fidelity color image acquisition requires an accurate characterization of the camera’s spectral sensitivity curves to perform color calibration or spectral estimation. Several methods have been proposed to perform this task; these include characterizations via test charts, narrowband filters and methods utilizing a monochromator. In most publications, RGB cameras are characterized. In this...

متن کامل

Microprocessor automation of a UV-visible monochromator

Introduction Isolation of selected wavelengths of light with high resolution grating monochromators is a common operation in spectrochemical methods of analysis. Commercial monochromators and monochromator controllers are often unable to control the monochromator’s operating parameters with the resolution required in automated systems. If a monochromator is to be used in a completely automated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013