Selective detection of zwitterionic arginine with a new Zn(II)-terpyridine complex: potential application in protein labeling and determination.

نویسندگان

  • Xin Zhou
  • Xuejun Jin
  • Donghao Li
  • Xue Wu
چکیده

A new water-soluble receptor 1 has been synthesized and it showed selective recognition of zwitterionic arginine in aqueous media. Moreover, the receptor 1 could be regard as a facile tool for protein labeling and quantitative determination (LOD = 15 nM).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemically-Modified Activated Carbon with L-Arginine for Selective Solid Phase Extraction and Preconcentration of Metal Ions

In this study, a new sorbent of chemically-modified activated carbon with L-arginine (AC-Arg) has been produced as solid-phase extraction, to trace Zn(II) and Cd(II) ions in real samples, including soil and water samples, by Flame Atomic Absorption Spectrometry (FAAS). Once the surface coverage value is determined, the surface modification has been investigated and assessed, while having em...

متن کامل

Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid

Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...

متن کامل

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

Preconcentration of Zn(II) in Water Sample Using Modified NanoFiber

A new simple and reliable method for rapid and selective extraction and determination of trace levels of Zn(II) ion is developed. Zn(II) ions are adsorbed quantitatively during passage of aqueous samples through PET-AA/AAm nano fiber modified. Almost all matrix elements were found to pass through the nano fiber to drain. Modified Poly (ethylene terephthalate)-grafted-Acrylic acid/Acryl amide Na...

متن کامل

Preconcentration of Zn(II) in Water Sample Using Modified NanoFiber

A new simple and reliable method for rapid and selective extraction and determination of trace levels of Zn(II) ion is developed. Zn(II) ions are adsorbed quantitatively during passage of aqueous samples through PET-AA/AAm nano fiber modified. Almost all matrix elements were found to pass through the nano fiber to drain. Modified Poly (ethylene terephthalate)-grafted-Acrylic acid/Acryl amide Na...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical communications

دوره 47 13  شماره 

صفحات  -

تاریخ انتشار 2011