Increased cardiac output and microvascular blood flow during mild hemoconcentration in hamster window model.

نویسندگان

  • Judith Martini
  • Amy G Tsai
  • Pedro Cabrales
  • Paul C Johnson
  • Marcos Intaglietta
چکیده

The effect of small hematocrit (Hct) increases on cardiac index (cardiac output/body wt) and oxygen release to the microcirculation was investigated in the awake hamster window chamber model by means of exchange transfusions of homologous packed red blood cells. Increasing Hct between 8 and 13% from baseline increased cardiac index by 5-31% from baseline (P < 0.05) and significantly lowered systemic blood pressure (P < 0.05). The relationship between Hct and cardiac index is described by a second-order polynomial (R2 = 0.84; P < 0.05) showing that Hct increases up to 20% from baseline increase cardiac index, whereas increases over 20% from baseline decrease cardiac index. Combining this data with measurements of blood pressure allowed to determine total peripheral vascular resistance, which was a minimum at 8-13% Hct increase and was described by a second-order polynomial (R2 = 0.83; P < 0.05). Oxygen measurements in arterioles, venules, and the tissue at 8-13% Hct increase were identical to control; thus, as a consequence of increased flow and oxygen-carrying capacity, oxygen delivery and extraction increased, but the change was not statistically significant. Previous results with the same model showed that the observed effects are related to shear stress-mediated release of nitric oxide, an effect that should be also present in the heart microcirculation, leading to increased blood flow, myocardial oxygen consumption, and contractility. We conclude that a minimum viscosity level is necessary for generating the shear stress required for maintaining normal cardiovascular function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increased Cardiac Output and Microvascular Blood Flow during Mild Hemoconcentration in the Hamster Window Model

The effect of small hematocrit (Hct) increases on cardiac index (cardiac output / body weight) and oxygen release to the microcirculation was investigated in the awake hamster window chamber model, by means of exchange transfusions of homologous packed red blood cells. Increasing Hct between 8-13% from baseline increased cardiac index by 5 31% from baseline (P < 0.05) and significantly lowered ...

متن کامل

Microvascular oxygen distribution in awake hamster window chamber model during hyperoxia.

The microvascular effects and hemodynamic events following exposure to normobaric hyperoxia (because of inspiration of 100% O2) were studied in the awake hamster window chamber model and compared with normoxia. Hyperoxia increased arterial blood Po2 to 477.9 +/- 19.9 from 60.0 +/- 1.2 mmHg (P < 0.05). Heart rate and blood pressure were unaltered, whereas cardiac index was reduced from 196 +/- 1...

متن کامل

Plasma viscosity regulates systemic and microvascular perfusion during acute extreme anemic conditions.

The hamster window chamber model was used to study systemic and microvascular hemodynamic responses to extreme hemodilution with low- and high-viscosity plasma expanders (LVPE and HVPE, respectively) to determine whether plasma viscosity is a factor in homeostasis during extreme anemic conditions. Moderated hemodilution was induced by two isovolemic steps performed with 6% 70-kDa dextran until ...

متن کامل

Hemoconcentration during a prolonged stress task: associations with hemodynamic reactivity and microvascular permeability.

This study explored the association between stress-induced hemoconcentration and plasma colloid osmotic pressure, hemodynamic reactivity, and microvascular permeability during a protracted stress task in 26 healthy, young participants. Microvascular permeability was measured during rest using venous congestion plethysmography in a subsample of 13 participants. The task increased hematocrit, col...

متن کامل

EFFECTS OF HYPOXIC HYPOXIA AND CARBON MONOXIDE-INDUCED HYPOXIA ON THE CARDIOVASCULAR SYSTEM AND REGIONAL BLOOD FLOW OF THE ANESTHETIZED CAT

The purpose of this study was to investigate the potential responses of the cardiovascular system and regional blood flow to hypoxic hypoxia (BB) and to carbon monoxide (CO)-induced hypoxia (COH). Ten anesthetized cats were studied under two nonnoxic (control: CONT) and two hypoxic conditions. Four types of radioactive micro spheres were used to measure regional blood flow during CONT an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 291 1  شماره 

صفحات  -

تاریخ انتشار 2006