An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique
نویسندگان
چکیده
INTRODUCTION To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. METHODS For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. RESULTS After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. CONCLUSION Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging.
منابع مشابه
Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کاملComparison of “heart and lung volume absorbed dose” between electron and photon boost radiotherapy after breast conserving surgery
Background: Breast conserving surgery (BCS) followed by radiotherapy (RT) has been widely accepted as the standard treatment in early stages of invasive breast cancer. The standard technique of RT includes whole breast irradiation (WBI). Additional tumor bed boost irradiation has also an important role in the local tumor control. But there are various controversial delivery methods. The aim of ...
متن کاملUltrasound-guided boost irradiation of tumor cavity after lumpectomy in breast cancer
Background: After breast conserving surgery, most recurrences occur around the primary tumor site. This justifies the use of boost radiotherapy to the primary site of tumor. Surgical scar is not always a good surrogate for the location of the lumpectomy cavity. The aim of this study was to evaluate ultrasonic guidance for detection of the lumpectomy cavity after breast conserving surgery ...
متن کاملComparison of two radiation techniques in breast boost delivery
Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...
متن کامل