Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring.

نویسندگان

  • D S Bindra
  • Y Zhang
  • G S Wilson
  • R Sternberg
  • D R Thévenot
  • D Moatti
  • G Reach
چکیده

A new miniaturized glucose oxidase based needle-type glucose microsensor has been developed for subcutaneous glucose monitoring. The sensor is equivalent in shape and size to a 26-guage needle (0.45-mm o.d.) and can be implanted with ease without any incision. The novel configuration greatly facilitates the deposition of enzyme and polymer films so that sensors with characteristics suitable for in vivo use (upper limit of linear range greater than 15 mM, response time less than 5 min, and sensitivity yielding a 5:1 signal-to-background ratio at normal basal glucose levels) can be prepared in high yield (greater than 60%). The sensor response is largely independent of oxygen tension in the normal physiological range. It also exhibits good selectivity against common interferences except for the exogenous drug acetaminophen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overview of a novel sensor for continuous glucose monitoring.

The core element of a continuous glucose monitoring (CGM) system is the glucose sensor, which should enable reliable CGM readings in the interstitial fluid in subcutaneous tissue for a period of several days. The aim of this article is to describe the layout and constituents of a novel glucose sensor and the rationale behind the measures that were used to optimize its performance. In order to a...

متن کامل

Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients.

OBJECTIVE We examined the reliability of two continuous glucose sensors in type 1 diabetic patients at night and during rapid glucose excursions and verified the hypothesized nocturnal hypoglycemic drift of the needle-type sensor (CGMSgold) and delay of the microdialysis sensor (GlucoDay). RESEARCH DESIGN AND METHODS Blood was sampled overnight twice per hour in 13 patients. Rapid-acting insu...

متن کامل

Design and fabrication of a rapid conductometric pH sensor based on metal-oxide technology

A micro-fabricated metal-oxide based conductometric pH sensor is designed and fabricated in this manuscript. pH sensors have applications in various areas from farming to food processing, human health monitoring, industrial waste products investigation, etc. Accordingly, there is a relatively high demand for a reliable, rapid and precise pH sensor in the market. Relatively precise pH sensors ha...

متن کامل

Characterization of porous, dexamethasone-releasing polyurethane coatings for glucose sensors.

Commercially available implantable needle-type glucose sensors for diabetes management are robust analytically but can be unreliable clinically primarily due to tissue-sensor interactions. Here, we present the physical, drug release and bioactivity characterization of tubular, porous dexamethasone (Dex)-releasing polyurethane coatings designed to attenuate local inflammation at the tissue-senso...

متن کامل

Current Application of Continuous Glucose Monitoring in the Treatment of Diabetes

The ultimate goal of diabetes technology is to create an artificial pancreas, or closed-loop system. In the early 1970s, the first prototypes became available (1). Although recent advances are promising, the closed-loop system is currently confined to the clinical research center (2). The continuous subcutaneous insulin infusion (CSII) pump became commercially available in the 1980s, and it is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 63 17  شماره 

صفحات  -

تاریخ انتشار 1991