Reliability issues for a bolometer detector for ITER at high operating temperatures.

نویسندگان

  • H Meister
  • M Kannamüller
  • J Koll
  • A Pathak
  • F Penzel
  • T Trautmann
  • P Detemple
  • S Schmitt
  • H Langer
چکیده

The first detector prototypes for the ITER bolometer diagnostic featuring a 12.5 μm thick Pt-absorber have been realized and characterized in laboratory tests. The results show linear dependencies of the calibration parameters and are in line with measurements of prototypes with thinner absorbers. However, thermal cycling tests up to 450 °C of the prototypes with thick absorbers demonstrated that their reliability at these elevated operating temperatures is not yet sufficient. Profilometer measurements showed a deflection of the membrane hinting to stresses due to the deposition processes of the absorber. Finite element analysis (FEA) managed to reproduce the deflection and identified the highest stresses in the membrane in the region around the corners of the absorber. FEA was further used to identify changes in the geometry of the absorber with a positive impact on the intrinsic stresses of the membrane. However, further improvements are still necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“N” structure for type-II superlattice photodetectors

Related Articles Gallium free type II InAs/InAsxSb1-x superlattice photodetectors Appl. Phys. Lett. 101, 071111 (2012) Influence of delta-doping on the performance of Ge/Si quantum-dot mid-infrared photodetectors J. Appl. Phys. 112, 034511 (2012) Broadband InGaAs-capped InAs/GaAs quantum-dot infrared photodetector with Bi-modal dot height distributions J. Appl. Phys. 112, 034508 (2012) Reliabil...

متن کامل

Optimization of a bolometer detector for ITER based on Pt absorber on SiN membrane.

Any plasma diagnostic in ITER must be able to operate at temperatures in excess of 200 °C and neutron loads corresponding to 0.1 dpa over its lifetime. To achieve this aim for the bolometer diagnostic, a miniaturized metal resistor bolometer detector based on Pt absorbers galvanically deposited on SiN membranes is being developed. The first two generations of detectors featured up to 4.5 μm thi...

متن کامل

The ITER bolometer diagnostic: status and plans.

A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R&D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in IT...

متن کامل

Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes.

The energy resolved efficiency of two bolometer detector prototypes for ITER with 4 channels each and absorber thicknesses of 4.5 μm and 12.5 μm, respectively, has been calibrated in a broad spectral range from 1.46 eV up to 25 keV. The calibration in the energy range above 3 eV was performed against previously calibrated silicon photodiodes using monochromatized synchrotron radiation provided ...

متن کامل

Efficiency calibration of ITER bolometer prototypes Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes

Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes H Meister, M Willmeroth, a) D Zhang, and , A Gottwald, M Krumrey, F Scholze Max-Planck-Institut für Plasmaphysik (IPP), EURATOM Association, Boltzmannstr. 2, 85748 Garching, Germany Max-Planck-Institut für Plasmaphysik (IPP), EURATOM Association, Teilinstitut Greifswald, Wendelsteinstraße 1, 17491...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 83 10  شماره 

صفحات  -

تاریخ انتشار 2012