Normal values of short-wavelength automated perimetry.
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate short-wavelength automated perimetry (SWAP, i.e., blue-yellow) in normal volunteers and to review the current normal values provided by the manufacturer. METHODS 28 eyes of 28 normal subjects (age range 21-48 years, mean age 36.5 years) had SWAP (Octopus 101, two phases of program G2, Interzeag AG, Schlieren, Switzerland). All subjects had normal eye examinations, refractive errors with spherical equivalents <5 diopters and astigmatism <2 diopters, normal intraocular pressures, no history of diseases affecting the visual field or nerve fiber layer, and normal white-white automated perimetry (Octopus 101, program G2). RESULTS 21% of the subjects (6/28) had to be excluded since visual field testing was not reliable (reliability factor >5%). With the normal values provided by the manufacturer, only 45% of the remaining subjects (10/22) had all other indices within normal limits. With the appropriate normal values based on the multicenter SWAP Octopus 101 study, 11% (3/28) were beyond the normal range: all had abnormal high sensitivities - 2 due to false-positive response. The normal value range for the index Mean Defect is remarkably wide (5.-, median, 95.- percentile: -4.4, -0.5, +5.3 dB, respectively). The normal value range for the index Loss Variance is surprisingly low and similar to standard perimetry (5.-, median, 95.- percentile: -1.7, 6.8, +21.2 dB(2), respectively). CONCLUSION SWAP with the Octopus G2 program reaches appropriate specificity but only if the correct normal values of the multicenter SWAP Octopus 101 study are used. The variability between subjects is remarkably large. The variability within a visual field is similar for SWAP and standard perimetry as reflected by similar values for the visual field index Loss Variance. Further studies have to establish the sensitivity to detect a disease for SWAP on the Octopus 101.
منابع مشابه
Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.
PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...
متن کاملEffect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma
PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinte...
متن کاملTopography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.
BACKGROUND Traquair described the topography of visual field sensitivity as a "hill" or "island" of vision. Achromatic automated perimetry (AAP) demonstrates this shape of the visual field in photopic conditions. Techniques claimed to target the magnocellular pathway (frequency doubling perimetry, FDP) and those using a stimulus targeting the koniocellular pathway (short wavelength (or blue on ...
متن کاملStatistical aspects of the normal visual field in short-wavelength automated perimetry.
PURPOSE To determine the intraindividual and interindividual characteristics of normal sensitivity derived by short-wavelength automated perimetry (SWAP) as a function of threshold algorithm. To determine also the influence of ocular media absorption on the magnitude of the interindividual variation in normal sensitivity, and hence the confidence limits, derived by SWAP. METHODS The sample co...
متن کاملComparison of Standard Automated Perimetry, Short-Wavelength Automated Perimetry, and Frequency-Doubling Technology Perimetry to Monitor Glaucoma Progression
Detection of progression is paramount to the clinical management of glaucoma. Our goal is to compare the performance of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry in monitoring glaucoma progression.Longitudinal data of paired SAP, SWAP, and FDT from 113 eyes with primary open-angle glaucoma enrolled in the D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde
دوره 217 4 شماره
صفحات -
تاریخ انتشار 2003