Note: Microelectromechanical systems Coulter counter for cell monitoring and counting.

نویسندگان

  • Yifan Wu
  • James D Benson
  • John K Critser
  • Mahmoud Almasri
چکیده

This note describes the design, fabrication, and testing of a novel microelectromechanical systems Coulter counter. The Coulter counter will be used to detect and monitor impedance changes of cells as a function of time in response to different experimental extracellular environments. The device consists of SU-8 (negative photoresist) microchannels, vertical electroplated electrodes, polydimethylsiloxane cover, and is divided into a passive mixing region, a focusing region using negative dielectrophoretic forces, and a measuring region defined by multiple electroplated electrode pairs. The devices were tested using both microbeads in saline water and fibroblast cells in phosphate buffered saline solution. The results show that the proposed microsystem is capable of monitoring impedance of cells at different positions along the Coulter microchannel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane

This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...

متن کامل

Platelet counting using the Coulter electronic counter.

A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

متن کامل

Automatic platelet counting with the Couler particle counter.

A method for accurately counting platelets is described using the Coulter counter model B fitted with a standard 100mu aperture tube. This enables the counter to be used for red and white cell as well as platelet counts using the same aperture tube. The method uses standard equipment except for a small inexpensive electronic speed controller.

متن کامل

Some problems in the use of the Coulter counter for erythrocyte total counts and volume distribution.

Normal erythrocytes were subject to swelling and some haemolysis when suspended in a NaCl-formaldehyde-Na(2)EDTA diluent of pH 4.9 for routine blood-cell counting in the Coulter counter. A phosphate-buffered saline of pH 7.4 was substituted and has proven satisfactory for total erythrocyte counts. Polyvinyltoluene latex was unsuitable for volume calibration of the counter, because of aggregatio...

متن کامل

Enumeration of platelets using a model B counter.

an engraved counting chamber and a light microscope, have many possibilities of error. The introduction of phase-contrast microscopy by Brecher, Schneiderman, and Cronkite (1953) has greatly facilitated the counting of platelets and improved the accuracy of the results. However, despite this improvement in accuracy the visual method is lacking in one basic essential, namely, speed in producing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 7  شماره 

صفحات  -

تاریخ انتشار 2010