Significance of a clean-tip catheter closed suctioning system in a high-setting ventilated, super morbidly obese patient with profuse respiratory secretions

نویسندگان

  • Mohd Zulfakar Mazlan
  • Rhendra Hardy Mohd Zaini
  • Shamsul Kamalrujan Hassan
  • Saedah Ali
  • Sanihah Che Omar
  • Wan Mohd Nazaruddin Wan Hassan
چکیده

INTRODUCTION Closed suctioning is commonly used in the context of high-setting mechanical ventilation (MV), given its ability to prevent lung volume loss that otherwise accompanies open suctioning. However, closed suctioning systems (CSS) are not equivalent regarding components and capabilities, and thus this technique may be differentially effective to adequately clear patient secretions from an endotracheal tube (ETT), which is of paramount importance when the tube size makes the ETT particularly vulnerable to block by patient secretions. CASE PRESENTATION A 25-year-old super morbidly obese female (body mass index = 55 kg/meter2) presented with worsening shortness of breath. For MV, pairing of a 6 mm (mm) diameter ETT to accommodate the patient's vocal cord edema, with a CSS not designed to maintain a clean catheter tip, precipitated ETT blockage and respiratory acidosis. Replacement of these devices with a 6.5 mm ETT and a CSS designed to keep the catheter tip clean resolved the complications. After use of the different ETT and CSS for approximately one week, the patient was discharged to home. DISCUSSION The clean-tip catheter CSS enabled a more patent airway than its counterpart device that did not have this feature. Use of a clean-tip catheter CSS was an important care development for this patient, because this individual's super morbidly obese condition minimized tolerance for MV complications that would exacerbate her pre-existing tenuous respiratory health status. CONCLUSION Special attention should be given to the choices of ETT size and CSS to manage super morbidly obese patients who have a history of difficult airway access.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abnormally increased power of breathing as a complication of closed endotracheal suction catheter systems.

Tracheobronchial suctioning is an essential part of routine care for mechanically ventilated patients. Closed, rather than open, suction catheters are preferred for their advantages, which include minimizing risk of hypoxemia and containment of potentially infected secretions during suctioning.1,2 A closed-suction catheter is situated between the endotracheal tube (ETT) and the Y-piece of the b...

متن کامل

AARC Clinical Practice Guidelines. Endotracheal suctioning of mechanically ventilated patients with artificial airways 2010.

An electronic literature search for articles published between January 1990 and October 2009 was conducted by using MEDLINE, CINAHL, and Cochrane Library databases. The update of this clinical practice guideline is the result of reviewing a total of 114 clinical trials, 62 reviews and 6 meta-analyses on endotracheal suctioning. The following recommendations are made following the Grading of Rec...

متن کامل

Endotracheal suctioning may or may not have an impact, but it does depend on what you measure!

Endotracheal suctioning is reportedly essential to maintain patency of an artificial airway in intubated and mechanically ventilated patients. However, the effectiveness of endotracheal suctioning alone to maintain airway patency is unclear. Endotracheal suctioning may also be associated with short-term physiological complications, such as lung de-recruitment and resultant hypoxemia in patients...

متن کامل

Secretion management in the mechanically ventilated patient.

Secretion management in the mechanically ventilated patient includes routine methods for maintaining mucociliary function, as well as techniques for secretion removal. Humidification, mobilization of the patient, and airway suctioning are all routine procedures for managing secretions in the ventilated patient. Early ambulation of the post-surgical patient and routine turning of the ventilated ...

متن کامل

The Effects of Rib Cage Compression before endotracheal suctioning

Abstract Introduction: Accumulation of secretions in airways is a serious complication in intubated and mechanically ventilated patients. Tracheal suctioning which is done with the aim of secretion removal can be used in conjunction with physiotherapy for effective airway clearance and improving gas exchange. Objective: The aim of study was to determine the effects of rib cage compression befor...