Passive Shimming of MRI Static Magnetic Field Using Regularization of Truncated Singular Value Decomposition

نویسنده

  • Mitsushi Abe
چکیده

PURPOSE To develop a new shimming calculation method, which can calculate iron piece placements rapidly to make the magnetic field homogeneous at intended homogeneity and then to make the shimming working time short. MATERIALS AND METHODS The shimming calculation yields magnetic moment (MM) distribution, which is calculated by the truncated singular value decomposition (SVD) from the measured magnetic field. The MM distribution is described by a superposition of eigenmodes obtained by SVD of a response matrix from the moment distributions to magnetic fields at the field of view (FOV). The homogeneity is regulated by a truncation number of the superposed eigenmodes. The magnetic moments are converted into iron volumes with the assumption of saturated magnetization and the iron pieces are placed according to the calculation results. Since the SVD calculation can be done in advance, the computational time at the shimming site is short. RESULTS Trial applications on a 0.5T magnetic resonance imaging (MRI) magnet were done using the new shimming calculation method, which was proved to work well. However, since the iron piece volumes had tolerances, the work was repeated until enough homogeneity was obtained. As a result, an intended homogeneity of 8.9 ppm (peak-to-peak) on 40 cm diameter spherical surface was successfully obtained from measured homogeneity of 543 ppm with short computational and working time. CONCLUSION The test shimming work showed that the developed shimming calculation method with truncated SVD regularization is applicable to the shimming work on the MRI magnets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large-scale Inversion of Magnetic Data Using Golub-Kahan Bidiagonalization with Truncated Generalized Cross Validation for Regularization Parameter Estimation

In this paper a fast method for large-scale sparse inversion of magnetic data is considered. The L1-norm stabilizer is used to generate models with sharp and distinct interfaces. To deal with the non-linearity introduced by the L1-norm, a model-space iteratively reweighted least squares algorithm is used. The original model matrix is factorized using the Golub-Kahan bidiagonalization that proje...

متن کامل

روش‌های تجزیه مقادیر منفرد منقطع و تیخونوف تعمیم‌یافته در پایدارسازی مسئله انتقال به سمت پائین

The methods applied to regularization of the ill-posed problems can be classified under “direct” and “indirect” methods. Practice has shown that the effects of different regularization techniques on an ill-posed problem are not the same, and as such each ill-posed problem requires its own investigation in order to identify its most suitable regularization method. In the geoid computations witho...

متن کامل

Deconvolution for DCE-MRI using an exponential approximation basis

A deconvolution approach for dynamic contrast enhanced magnetic resonance imaging using an approximation basis of exponential functions constrained to be non-negative and non-increasing is developed and compared with widely used methods. Monotonicity in an exponential basis is implemented in terms of a newly derived condition which is a considerable generalization over a previous condition that...

متن کامل

A 3-D spatio-temporal deconvolution approach for MR perfusion in the brain

We propose an original spatio-temporal deconvolution approach for perfusion-weighted MRI applied to cerebral ischemia. The regularization of the underlying inverse problem is achieved with spatio-temporal priors and the resulting optimization problem is solved by half-quadratic minimization. Our approach offers strong convergence guarantees, including when the spatial priors are non-convex. Mor...

متن کامل

Regularized higher-order in vivo shimming.

A regularized algorithm is presented for localized in vivo shimming. The technique uses first- (X,Y,Z), second- (Z(2), ZX, ZY, X(2)-Y(2), XY), and third-order (Z(3)) shim coils, and is robust when applied to arbitrarily-shaped, as well as off-center, regions of interest (ROIs). A single-shot spiral pulse sequence is used for rapid field map acquisition, and a least-squares calculation of the sh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017