Quantification of myocardial perfusion with self-gated cardiovascular magnetic resonance

نویسندگان

  • Devavrat Likhite
  • Ganesh Adluru
  • Nan Hu
  • Chris McGann
  • Edward DiBella
چکیده

BACKGROUND Current myocardial perfusion measurements make use of an ECG-gated pulse sequence to track the uptake and washout of a gadolinium-based contrast agent. The use of a gated acquisition is a problem in situations with a poor ECG signal. Recently, an ungated perfusion acquisition was proposed but it is not known how accurately quantitative perfusion estimates can be made from such datasets that are acquired without any triggering signal. METHODS An undersampled saturation recovery radial turboFLASH pulse sequence was used in 7 subjects to acquire dynamic contrast-enhanced images during free-breathing. A single saturation pulse was followed by acquisition of 4-5 slices after a delay of ~40 msec. This was repeated without pause and without any type of gating. The same pulse sequence, with ECG-gating, was used to acquire gated data as a ground truth. An iterative spatio-temporal constrained reconstruction was used to reconstruct the undersampled images. After reconstruction, the ungated images were retrospectively binned ("self-gated") into two cardiac phases using a region of interest based technique and deformably registered into near-systole and near-diastole. The gated and the self-gated datasets were then quantified with standard methods. RESULTS Regional myocardial blood flow estimates (MBFs) obtained using self-gated systole (0.64 ± 0.26 ml/min/g), self-gated diastole (0.64 ± 0.26 ml/min/g), and ECG-gated scans (0.65 ± 0.28 ml/min/g) were similar. Based on the criteria for interchangeable methods listed in the statistical analysis section, the MBF values estimated from self-gated and gated methods were not significantly different. CONCLUSION The self-gated technique for quantification of regional myocardial perfusion matched ECG-gated perfusion measurements well in normal subjects at rest. Self-gated systolic perfusion values matched ECG-gated perfusion values better than did diastolic values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software

Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

Inter-study repeatability of self-gated CMR perfusion: A comparison of Fermi and compartment models

Background Recent developments in cardiovascular magnetic resonance (CMR) perfusion have made it possible to rapidly acquire multiple slices continuously without the need for any ECG-triggering. Promising results have been shown for visual assessment and quantification of perfusion using self-gated techniques [1-3]. This work compares the repeatability of a free breathing ungated acquisition us...

متن کامل

Quantification of myocardial perfusion by cardiovascular magnetic resonance

The potential of contrast-enhanced cardiovascular magnetic resonance (CMR) for a quantitative assessment of myocardial perfusion has been explored for more than a decade now, with encouraging results from comparisons with accepted "gold standards", such as microspheres used in the physiology laboratory. This has generated an increasing interest in the requirements and methodological approaches ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -