Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry.

نویسندگان

  • J L Vílchez
  • A Prieto
  • L Araujo
  • A Navalón
چکیده

A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of Disinfection By-products in Water Samples from Advanced Membrane Treatments by Headspace Solid Phase Microextraction and Gas Chromatography-Mass Spectrometry

A headspace-solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) method has been developed for the simultaneously determination of 20 disinfection by-products (DBPs) in water samples from reverse osmosis (RO) membranes. Selected compounds belong to different families including: trihalomethanes (THMs), halogenated acetonitriles (HANs), halogenated nitromethanes ...

متن کامل

Determination of Volatiles in Beer using Solid-Phase Microextraction in Combination with Gas Chromatography/Mass Spectrometry

Kleinová J., Klejdus B. (2014): Determination of volatiles in beer using solid-phase microextraction in combination with gas chromatography/mass spectrometry. Czech J: Food Sci., 32: 241–248. Headspace solid phase microextraction and purge and trap analysis were used for the determination of volatiles in beer. These methods were compared with the analysis of unconcentrated gas phase and liquid ...

متن کامل

Determination of major aroma impact compounds in fermented cucumbers by solid-phase microextraction--gas chromatography--mass spectrometry--olfactometry detection.

Purge-and-trap, solid-phase extraction, and solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) sample preparation techniques for the analysis of odor impact chemicals in fermented cucumber brine are compared. SPME-GC-MS is coupled with detection frequency olfactometry experiments to determine key impact odor compounds in the brine. The most potent odorants that define...

متن کامل

Detection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography

Migration of chemicals from plastic containers into drinks and liquids containing them, is supposed to be a hazardous phenomenon and results in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid–liquid microextraction is applied for the extraction and preconcentration of the migrated compounds pri...

متن کامل

Simple Determination of Dimethylsulfide (DMS) and Dimethylsulfoniopropionate (DMSP) Using Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry

Solid-phase microextraction (SPME) is a simple, sensitive and less destructive method for the determination of dimethylsulfide (DMS) in seawater. Combined with detection by gas chromatography-mass spectrometry (GC-MS), the method had sufficient sensitivity (minimum detectable concentration of DMS was 0.05 nM), and practical levels of reproducibility (relative standard deviation ≤7%) and lineari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 919 1  شماره 

صفحات  -

تاریخ انتشار 2001