Electron and ion imaging of gland cells using the FIB/SEM system.

نویسندگان

  • D Drobne
  • M Milani
  • A Zrimec
  • V Leser
  • M Berden Zrimec
چکیده

The FIB/SEM system was satisfactorily used for scanning ion (SIM) and scanning electron microscopy (SEM) of gland epithelial cells of a terrestrial isopod Porcellio scaber (Isopoda, Crustacea). The interior of cells was exposed by site-specific in situ focused ion beam (FIB) milling. Scanning ion (SI) imaging was an adequate substitution for scanning electron (SE) imaging when charging rendered SE imaging impossible. No significant differences in resolution between the SI and SE images were observed. The contrast on both the SI and SE images is a topographic. The consequences of SI imaging are, among others, introduction of Ga(+) ions on/into the samples and destruction of the imaged surface. These two characteristics of SI imaging can be used advantageously. Introduction of Ga(+) ions onto the specimen neutralizes the charge effect in the subsequent SE imaging. In addition, the destructive nature of SI imaging can be used as a tool for the gradual removal of the exposed layer of the imaged surface, uncovering the structures lying beneath. Alternative SEM and SIM in combination with site-specific in situ FIB sample sectioning made it possible to image the submicrometre structures of gland epithelium cells with reproducibility, repeatability and in the same range of magnifications as in transmission electron microscopy (TEM). At the present state of technology, ultrastructural elements imaged by the FIB/SEM system cannot be directly identified by comparison with TEM images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface damage induced by FIB milling and imaging of biological samples is controllable.

Focused ion beam (FIB) techniques are among the most important tools for the nanostructuring of surfaces. We used the FIB/SEM (scanning electron microscope) for milling and imaging of digestive gland cells. The aim of our study was to document the interactions of FIB with the surface of the biological sample during FIB investigation, to identify the classes of artifacts, and to test procedures ...

متن کامل

Comparison of different preparation methods of biological samples for FIB milling and SEM investigation.

When a new approach in microscopy is introduced, broad interest is attracted only when the sample preparation procedure is elaborated and the results compared with the outcome of the existing methods. In the work presented here we tested different preparation procedures for focused ion beam (FIB) milling and scanning electron microscopy (SEM) of biological samples. The digestive gland epitheliu...

متن کامل

Human cardiac telocytes: 3D imaging by FIB-SEM tomography

Telocyte (TC) is a newly identified type of cell in the cardiac interstitium (www.telocytes.com). TCs are described by classical transmission electron microscopy as cells with very thin and long telopodes (Tps; cellular prolongations) having podoms (dilations) and podomers (very thin segments). TCs' three-dimensional (3D) morphology is still unknown. Cardiac TCs seem to be particularly involved...

متن کامل

Sem/fib Stage Calibration with Photogrammetric Methods

Precise sample stage positioning plays an important role for various FIB (Focused Ion Beam) and SEM (scanning electron microscope) applications in microand nanotechnology. During the last few years, FIB instruments have become an indispensable tool for sample preparation, prototyping and micro-machining. Modern FIB devices are equipped with an additional electron column. Such combined SEM/FIB d...

متن کامل

Tomography of insulating biological and geological materials using focused ion beam (FIB) sectioning and low-kV BSE imaging.

Tomography in a focused ion beam (FIB) scanning electron microscope (SEM) is a powerful method for the characterization of three-dimensional micro- and nanostructures. Although this technique can be routinely applied to conducting materials, FIB-SEM tomography of many insulators, including biological, geological and ceramic samples, is often more difficult because of charging effects that distu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of microscopy

دوره 219 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2005