Aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis. Clinical experiences in 50 cases.

نویسندگان

  • T K Larmi
  • P Kärkölä
  • J Takkunen
چکیده

Single aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis has been performed in 50 patients since April 1971. None of the total of six deaths (12.0%) was attributable to malfunction of the prosthesis or to embolic complications. Follow-up examination showed insignificant or moderate prosthetic regurgitation in two patients and moderate paravalvular leakage in one patient. A slight intravascular haemolysis was found in two cases, one of them without marked regurgitation, and a slight reversible cerebral thrombo-embolism in two. Clinical improvement was observed in 43 of the 44 survivors during the 6 to 12 months of follow-up. Objective evidence of improvement was verified by cardiac catheterization following the replacement of aortic valve with the Björk-Shiley tilting disc prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic valve replacement in patients over 70 years.

Twenty-seven patients 70 years of age or more were operated upon with aortic valvular replacement with an early mortality rate of 7%. No more patients died during a mean follow-up period of 28 months. The Björk-Shiley standard tilting disc valve was implanted in 15 cases and the new convexo-concave model in 12 cases. Sixty-seven per cent of the patients had narrow aortic roots (21 and 23 mm pro...

متن کامل

Results of use of the pyrolytic carbon tilting disc Bjork-Shiley aortic prosthesis.

Replacement of the aortic valve with a new BjorkShiley prosthesis was performed in 1 10 patients during the period from November, 1971 to July, 1973. The previously reported Delrin-disc Bjork-Shiley valve had a built-in valvular leak of up to 10 percent due to .003” clearance. The new pyrolite-disc prosthesis is machined to a clearance of .001”. Excellent clinical results have been achieved in ...

متن کامل

Red cell survival after aortic valve replacement with Björk-Shiley prosthesis in presence of sickle-cell trait.

A case of aortic valve replacement with a Björk-Shiley disc prosthesis in a patient with sickle-cell trait is presented. Six months after operation red cell survival was not significantly reduced. On theoretical and clinical grounds it is concluded that the presence of sickle-cell trait does not contribute to late postoperative haemolysis after heart valve replacement.

متن کامل

Haemolysis after mitral valve replacement with the Björk-Shiley and the Lillehei-Kaster disc valve prosthesis.

The present study reports on the incidence and degree of intravascular haemolysis in 33 patients with Björk-Shiley tilting disc prosthesis and in 34 patients with Lillehei-Kaster pivoting disc valve prosthesis in the mitral position examined 12 to 24 months after the operation. Serum haptoglobin, serum lactate dehydrogenase, serum bilirubin, and haemoglobin estimations were performed. Significa...

متن کامل

Anticoagulants and the Björk-Shiley prosthesis. Experience of 390 patients.

From September 1972 to January 1975, 390 patients underwent valve replacement using the Björk-Shiley tilting disc prosthesis. For the group as a whole hospital mortality was 13.3 per cent and was lowest in those undergoing isolated mitral or aortic valve replacement (5.3 and 9.4%, respectively). Available for follow-up were 209 patients of whom 123 were maintained on dipyridamole and 96 on warf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Scandinavian journal of thoracic and cardiovascular surgery

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 1971