Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement
نویسندگان
چکیده
OBJECTIVE This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. METHODS Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. RESULTS There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). CONCLUSION This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.
منابع مشابه
بررسی و مقایسه مقادیر فشار سیستولیک اندازه گیری شده بوسیله قسمت دیافراگم و بل گوشی در بیماران بستری در بیمارستان شهید بهشتی کاشان در سال 1372
This is a 9uasi experimental study to compare blood pressure measurements taken by both components of stethoscope, bell and diaphragm. Blood pressure was evaluated in fifty patients of fifteen years of age and older. Equal populations of both genders were selected randomly from infectious, surgery and internal medicine wards. Subjects with cardiac arrhythmia weren't included in the study. Fiv...
متن کاملمقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی
Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...
متن کاملThe stethoscope: some preliminary investigations.
Textbooks, clinicians, and medical teachers differ as to whether the stethoscope bell or diaphragm should be used for auscultating respiratory sounds at the chest wall. Logic and our results suggest that stethoscope diaphragms are more appropriate.
متن کاملPredictors of stethoscope contamination following a standardized physical exam
Methods Following a standardized physical exam using sterile gloves and a sterile stethoscope, bacterial contamination of the following regions were assessed using contact plates: stethoscope diaphragm, stethoscope tube, fingertips, thenar region, hypothenar region and back of physician’s dominant hand. Total aerobic colony count (ACC) were determined on digital photographs using a counting tool.
متن کاملThe stethoscope - a vector of infection?
The Stethoscope— A Vector of Infection? To the Editor: In the course of investigating a hospital-wide outbreak of methicillin resistant Staphylococcus aureus, 67 physicians' stethoscopes were cultured. Both the bell and the diaphragm were sampled with a sterile cotton swab, and this was immediately streaked onto Columbia Nutrient Agar (BBL), a selective medium for grampositive organisms. The ca...