Q-space truncation and sampling in diffusion spectrum imaging.
نویسندگان
چکیده
PURPOSE To characterize the q-space truncation and sampling on the spin-displacement probability density function (PDF) in diffusion spectrum imaging (DSI). METHODS DSI data were acquired using the MGH-USC connectome scanner (Gmax = 300 mT/m) with bmax = 30,000 s/mm2 , 17 × 17 × 17, 15 × 15 × 15 and 11 × 11 × 11 grids in ex vivo human brains and bmax = 10,000 s/mm2 , 11 × 11 × 11 grid in vivo. An additional in vivo scan using bmax =7,000 s/mm2 , 11 × 11 × 11 grid was performed with a derated gradient strength of 40 mT/m. PDFs and orientation distribution functions (ODFs) were reconstructed with different q-space filtering and PDF integration lengths, and from down-sampled data by factors of two and three. RESULTS Both ex vivo and in vivo data showed Gibbs ringing in PDFs, which becomes the main source of artifact in the subsequently reconstructed ODFs. For down-sampled data, PDFs interfere with the first replicas or their ringing, leading to obscured orientations in ODFs. CONCLUSION The minimum required q-space sampling density corresponds to a field-of-view approximately equal to twice the mean displacement distance (MDD) of the tissue. The 11 × 11 × 11 grid is suitable for both ex vivo and in vivo DSI experiments. To minimize the effects of Gibbs ringing, ODFs should be reconstructed from unfiltered q-space data with the integration length over the PDF constrained to around the MDD. Magn Reson Med 76:1750-1763, 2016. © 2016 International Society for Magnetic Resonance in Medicine.
منابع مشابه
Dataset-independent reconstruction of high angular resolution diffusion sampling schemes by generalized q-space imaging
We propose a novel q-space imaging method called generalized q-space imaging (GQI), which is derived from the Fourier transform relationship between the MR signals and underlying diffusion displacement [1]. The method is characterized by being independent of the q-space sampling schemes, enabling us to use either q-ball imaging (QBI) [2] or diffusion spectrum imaging (DSI) dataset [3]. The accu...
متن کاملNon-Cartesian Compressed Sensing for Diffusion Spectrum Imaging
INTRODUCTION: One important limitation of DTI is its inability to resolve multiple crossing fibers within a voxel. Diffusion Spectrum Imaging (DSI) allows such resolution by Nyquist sampling a 3D q-space[1] for each voxel. The water displacement probability (“propagator”) corresponds to the Fourier transform of the MR signal as a function of q r . This high dimensionality imposes a trade-off be...
متن کاملCompressed Sensing based Diffusion Spectrum Imaging
Introduction: Several methods are currently used to resolve multiple fibers within a voxel including Q-space imaging such as DSI and QBI. These approaches are generally limited by the burden of dense sampling in Q-space to avoid aliasing, which makes their application to clinical studies difficult. However, compressed sensing (CS) can attain almost perfect reconstruction from incomplete random ...
متن کاملEstimation of fiber orientation and spin density distribution by diffusion deconvolution
A diffusion deconvolution method is proposed to apply deconvolution to the diffusion orientation distribution function (dODF) and calculate the fiber orientation distribution function (fODF), which is defined as the orientation distribution of the fiber spin density. The dODF can be obtained from q-space imaging methods such as q-ball imaging (QBI), diffusion spectrum imaging (DSI), and general...
متن کاملJoint 6D k-q Space Compressed Sensing for Accelerated High Angular Resolution Diffusion MRI
High Angular Resolution Diffusion Imaging (HARDI) avoids the Gaussian. diffusion assumption that is inherent in Diffusion Tensor Imaging (DTI), and is capable of characterizing complex white matter micro-structure with greater precision. However, HARDI methods such as Diffusion Spectrum Imaging (DSI) typically require significantly more signal measurements than DTI, resulting in prohibitively l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 76 6 شماره
صفحات -
تاریخ انتشار 2016