Human lens transmission of blue light: a comparison of autofluorescence-based and direct spectral transmission determination.
نویسندگان
چکیده
PURPOSE Direct measurement of the transmission of light through the human lens is not possible in vivo unless invasive techniques are used. In the current study, a reliable in vivo estimate of the transmission of blue light through the lens was assessed by comparing an indirect and noninvasive method based on autofluorescence measurements with a direct method. METHODS Total transmission of blue light was measured in human donor lenses using a direct method applicable only in vitro and compared with transmittance estimates made by an in vivo applicable autofluorescence technique. RESULTS Human lens transmission of blue light decreases with age by 0.7-0.8% per year at 480 nm. The comparison of methods showed that the autofluorescence-based method correlated significantly with the direct measurements (R = 0.83, p < 0.001) and acceptable agreement between the two methods was found. DISCUSSION In conclusion, the human lens transmittance of blue light can be measured reliably in vivo. This enables the possibility to correct for retinal light intensities when studying the mechanisms of the circadian rhythm in clinical studies and related disorders and in addition when working with clinical and experimental methods affected by retinal blue light intensities.
منابع مشابه
Lens transmission of blue-green light in diabetic patients as measured by autofluorophotometry.
Lens transmission for blue-green light (lambda = 490 nm and 530 nm) was assessed by means of fluorophotometry in 67 diabetic patients without cataracts and compared with that of 52 healthy controls. Lens transmission was determined from peak autofluorescence values in the anterior and posterior parts of the lens, assuming an about equal fluorescence peak quantum efficiency in both parts. The va...
متن کاملDetermination of Interfacial Area in Gas-Liquid Two Phase by Light Transmission
The purpose of the present paper is to develop light beam method to measurement of interfacial area in a rectangular gas-liquid bubble column. Total interfacial area can be determined in bubble column filled by transparent liquid by light transmission method. According to pervious researches, the fraction of parallel light is function of interfacial area and optical path l...
متن کاملMethylene Blue Based Device for Pathogen Reduction in Human Plasma
Abstract Background Despite improvement in safety of plasma transfusion some virus transmission still remains a problem. So as World Health Organization (WHO) recommends, many countries developed Pathogen Reduction Technologies (PRT) to inactivate pathogens, in plasma components. The Methylene Blue (MB) based methods is one of the most universal one. The purpose of this research was, produce...
متن کاملThe Effect of Lyophilization on Light Transmission of Amniotic Membrane: A Comparison with Rabbit Cornea
Background & Aims: Amniotic membrane persists for a long time after ocular transplantation (as corneal substitute) and can affect light transmission (transparency). The aim of this study was to evaluate the transparency of amniotic membrane after freeze-drying (lyophilization) and to compare the results with transparency of rabbit cornea. Methods: Transparency of rabbits’ corneas and fresh and ...
متن کاملMicrowave-assisted rapid synthesis of Co3O4 nanorods from CoC2O4.2H2O nanorods and its application in photocatalytic degradation of methylene blue under visible light irradiation
In this work, Co3O4 nanorods were successfully prepared by microwave-assisted solid state decomposition of rod-like CoC2O4.2H2O precursor within a very short reaction time (6 min) without the use of a solvent/surfactant and complicated equipment. The as-obtained Co3O4 nanorods were fully characterized by X-ray diffract...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic research
دوره 46 3 شماره
صفحات -
تاریخ انتشار 2011