Performance tests of three types of air-sampling bags on organic solvent vapor retention.

نویسندگان

  • Yoshinari Fukui
  • Ai Kanemaru
  • Yasuhiro Nagasawa
  • Takuya Kawakami
  • Toyoto Iwata
  • Katsuyuki Murata
  • Fumiko Ohashi
  • Masayuki Ikeda
چکیده

Performance of two new air sampling bags [the transparent bag (TP bag) and the semi-transparent bag (ST bag)] was examined as possible surrogates for the traditional PVF bag (the Ref bag). Solvent vapor mixture of butyl acetate, chloroform, ethyl acetate, isopropyl alcohol and toluene at administrative control levels were introduced to each bag (n=5 for each of the three types), and the decay in the concentrations (by%) was followed by use of a gas auto-sampler - FID-GC system. A trend of time-dependent decay was noted for all types including the Ref bag. When the performance was compared, the TP bag was equal to or even better than the Ref bag. In contrast, the performance of the ST bag was comparable to that of the other two types of bags with regard to toluene and chloroform when the storage time was short, but poorer than others for the other three solvents throughout the test period. The TP bag may be a bag of choice when the storage time is extended (e.g., up to 48 h) although this bag is physically less robust and requires careful handling. The ST bag may be used when analysis will be completed within 24 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adsorption efficiency of functionalized multi-walled carbon nanotube in sampling trichloroethylene in air

Introduction: Trichloroethylene (TCE) is an industrial solvent which is often used as a degreaser for metal parts. Due to adverse health effects and carcinogenic properties of this solvent, knowing its concentration in the workplace atmosphere is really crucial. Nowadays, carbon nanotubes with high efficiency are being used for sampling of this chemical. Method:</stron...

متن کامل

Analysis of solvent vapors in breath and ambient air with a surface acoustic wave sensor array.

This article describes the development and evaluation of a small prototype instrument employing an array of four polymer-coated surface acoustic wave (SAW) sensors for rapid analysis of organic solvent vapors in exhaled breath and ambient air. A thermally desorbed adsorbent preconcentrator within the instrument is used to increase sensitivity and compensate for background water vapor. Calibrati...

متن کامل

Analysis of Biogenic Volatile Organic Compounds in Air Using a Solid-Phase Extraction-Type Collection Device

In this study, the quantitative determination of gaseous biogenic volatile organic compounds (BVOCs) including monoterpenes and sesquiterpenes was accomplished using a solid-phase extraction-type collection device. The collection device was fabricated by packing styrene-divinylbenzene polymer particles into a specially designed glass cartridge. The retention performance of the collection device...

متن کامل

A small-volume constant-flow air sampling device for thermal desorption GC analysis.

A glass syringe with disposable membrane filters was tested as a constant-flow air sampling device. The principle of this sampling device is straightforward: when the syringe is inverted vertically, the syringe plunger falls at a constant speed if an appropriate flow restrictor is connected at the syringe inlet. In case of a 100 ml syringe with two Teflon membrane filters of 0.50 microns in por...

متن کامل

Relationship between exposure and environmental concentrations in organic solvent workplaces.

The correlation between the exposure concentration (ExpC) of workers and the environmental concentration (EnvC) in their workplaces were examined in 143 printing, painting, gluing, degreasing and other solvent workplaces manned by 535 workers of both sexes. ExpC was measured with carbon felt dosimeters, and EnvC was with grab sampling of air into poly-tetrafluoroethylene bags; both were followe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 51 3  شماره 

صفحات  -

تاریخ انتشار 2013