Measurement of Orbital Volume after Enucleation and Orbital Implantation

نویسندگان

  • Olga Lukats
  • Tamas Vízkelety
  • Zsolt Markella
  • Erika Maka
  • Maria Kiss
  • Adrienn Dobai
  • Peter Bujtár
  • Attila Szucs
  • Jozsef Barabas
چکیده

INTRODUCTION This article reports experience relating to the measurement of orbital volume by means of cone beam computed tomography (CBCT) and Cranioviewer program software in patients who have undergone enucleation and orbital implantation. PATIENTS AND METHODS CBCT scans were made in 30 cases, 10 of which were later excluded because of various technical problems. The study group therefore consisted of 20 patients (8 men and 12 women). The longest follow-up time was 7 years, and the shortest was 1 year. In all 20 cases, the orbital volume was measured with Cranioviewer orbital program software. Slices were made in the ventrodorsal direction at 4.8 mm intervals in the frontal plane, in both bony orbits (both that containing the orbital implant and the healthy one). Similar measurements were made in 20 patients with various dental problems. CBCT scans were recorded for the facial region of the skull, containing the orbital region. The Cranioviewer program can colour the area of the slices red, and it automatically measures the area in mm. RESULTS In 5 of the 20 cases, the first 4 or all 5 slices revealed that the volume of the operated orbit was significantly smaller than that of the healthy orbit, in 12 cases only from 1 to 3 of the slices indicated such a significant difference, and in 3 cases no differences were observed between the orbits. In the control group of patients with various dental problems, there was no significant difference between the two healthy orbits. The accuracy of the volume measurements was assessed statistically by means of the paired samples t-test. SUMMARY To date, no appropriate method is avaliable for exact measurement of the bony orbital volume, which would be of particular importance in orbital injury reconstruction. However, the use of CBCT scans and Cranioviewer orbital program software appears to offer a reliable method for the measurement of changes in orbital volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Rabbit orbital measure evaluations after enucleation and evisceration].

PURPOSE To assess orbital volume in weaned rabbits, submitted to enucleation and evisceration, with orbital volume reconstitution using porous polyethylene (PP) spheres, analyzed by computed tomography, by the water displacement test and external orbital measures using Image-J software. METHODS This experimental randomized study consisted of 48 albino rabbits, with 42 days of life, submitted ...

متن کامل

ß-tricalcium Phosphate Granules as an Alternative Material for Ocular Implantation

Background: Some types of implants used for orbital implantation have side effects and complications. In this study we have evaluated beta-tricalcium phosphate (ß-TCP: ChronOS) granules as an orbital implant. Methods: Eighteen rabbits randomly allocated to four groups. Right eye enucleation performed in groups I to III followed by filling with autologous bone particles (n=5), a mixture of autol...

متن کامل

Evaluation of efficacy and complications: primary pediatric orbital implants after enucleation.

BACKGROUND Orbital implants are used routinely in pediatric patients at the time of enucleation. Complications, such as exposure, ptosis, and infection, may occur after implantation. Controversy continues regarding the rate of complications with newer implants in the pediatric population. OBJECTIVE To examine the effects of orbital implants on children whose eyes have been enucleated. METHO...

متن کامل

Orbital growth after unilateral enucleation in infancy without an orbital implant.

PURPOSE To measure the volume of the anophthalmic orbit in adults who had undergone enucleation during infancy and to determine its growth. METHODS The orbital volume in 5 adults who had undergone unilateral enucleation during infancy without an orbital implant was measured on x-ray computed tomography images. Comparisons were made between the anophthalmic and normal sides. In addition, we ev...

متن کامل

The Survival of Freely Grafted Orbital Fat on Porous Polyethylene Orbital Implants in the Rabbit

PURPOSE To investigate the long term survival of orbital fat grafted on a Medpor implant as a method of preventing porous polyethylene orbital implant (Medpor) exposure in anophthalmic sockets. METHODS In one orbit in each of 8 rabbits, a small amount of retrobulbar orbital fat was grafted between the anterior surface of the Medpor implant and overlying conjunctiva, during the enucleation and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012