Liquid chromatography-mass spectrometry calibration transfer and metabolomics data fusion.
نویسندگان
چکیده
Metabolic profiling is routinely performed on multiple analytical platforms to increase the coverage of detected metabolites, and it is often necessary to distribute biological and clinical samples from a study between instruments of the same type to share the workload between different laboratories. The ability to combine metabolomics data arising from different sources is therefore of great interest, particularly for large-scale or long-term studies, where samples must be analyzed in separate blocks. This is not a trivial task, however, due to differing data structures, temporal variability, and instrumental drift. In this study, we employed blood serum and plasma samples collected from 29 subjects diagnosed with small cell lung cancer and analyzed each sample on two liquid chromatography-mass spectrometry (LC-MS) platforms. We describe a method for mapping retention times and matching metabolite features between platforms and approaches for fusing data acquired from both instruments. Calibration transfer models were developed and shown to be successful at mapping the response of one LC-MS instrument to another (Procrustes dissimilarity = 0.04; Mantel correlation = 0.95), allowing us to merge the data from different samples analyzed on different instruments. Data fusion was assessed in a clinical context by comparing the correlation of each metabolite with subject survival time in both the original and fused data sets: a simple autoscaling procedure (Pearson's R = 0.99) was found to improve upon a calibration transfer method based on partial least-squares regression (R = 0.94).
منابع مشابه
Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملMetabolic differences in ripening of Solanum lycopersicum ‘Ailsa Craig’ and three monogenic mutants
Application of mass spectrometry enables the detection of metabolic differences between groups of related organisms. Differences in the metabolic fingerprints of wild-type Solanum lycopersicum and three monogenic mutants, ripening inhibitor (rin), non-ripening (nor) and Colourless non-ripening (Cnr), of tomato are captured with regard to ripening behaviour. A high-resolution tandem mass spectro...
متن کاملComparative Metabolomics Analysis of Cervicitis in Human Patients and a Phenol Mucilage-Induced Rat Model Using Liquid Chromatography Tandem Mass Spectrometry
Citation: Zhang X, Li J, Xie B, Wu B, Lei S, Yao Y, He M, Ouyang H, Feng Y, Xu W and Yang S (2018) Comparative Metabolomics Analysis of Cervicitis in Human Patients and a Phenol Mucilage-Induced Rat Model Using Liquid Chromatography Tandem Mass Spectrometry. Front. Pharmacol. 9:282. doi: 10.3389/fphar.2018.00282 Comparative Metabolomics Analysis of Cervicitis in Human Patients and a Phenol Muci...
متن کاملAStream: an R package for annotating LC/MS metabolomic data
UNLABELLED AStream, an R-statistical software package for the curation and identification of feature peaks extracted from liquid chromatography mass spectrometry (LC/MS) metabolomics data, is described. AStream detects isotopic, fragment and adduct patterns by identifying feature pairs that fulfill expected relational patterns. Data reduction by AStream allows compounds to be identified reliabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 84 22 شماره
صفحات -
تاریخ انتشار 2012