Assessment of interrater and intrarater reliability in the evaluation of metered dose inhaler technique.

نویسندگان

  • S L Gray
  • A C Nance
  • D M Williams
  • C C Pulliam
چکیده

STUDY OBJECTIVE To determine if a training session using videotaped metered dose inhaler (MDI) performances can result in high interrater and intrarater reliability of five evaluators assessing MDI technique. DESIGN Five evaluators (three pharmacists, two pulmonary fellows) were trained to evaluate MDI technique during a 2-h training session. The training session consisted of verbal instruction and practical experience in evaluating MDI technique using video-taped MDI performances of six nonstudy subjects. After the training session, the evaluators independently observed the same videotaped MDI demonstrations of 14 subjects on two occasions separated by a 7- to 10-day interval. Interrater and intrarater reliability was determined for individual steps by calculating percent agreement and intraclass correlation (ICC) coefficient. RESULTS Interrater. The interrater reliability for individual steps ranged from 29 to 86 percent (ICC coefficient = 0.13 to 0.81). Steps in which evaluators were in agreement for less than 9 of the 14 subjects were shaking the inhaler before inhalation, exhaling, continuing to inhale slowly, and adequate breath hold. Intrarater: The overall percent agreement by step ranged from 74 to 97 percent. Exhaling to functional residual volume (76 percent) and continuing to inhale slowly and deeply (74 percent) had the lowest overall agreement between the first and second observation day. The consistency of evaluating a step between the two observation days varied considerably depending on the step and evaluator. CONCLUSIONS High interrater and intrarater reliability in MDI evaluation is difficult to obtain. Clinicians and researchers involved in MDI evaluation and education should be trained to achieve consistency. A single training session using videotaped MDI demonstrations was not adequate in achieving consistency among evaluators. To improve accuracy of research results, researchers should include at least two evaluators to assess MDI technique or take other measures to show and report reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of the visual assessment of cervical and lumbar lordosis: how good are we?

STUDY DESIGN Blinded test-retest design. OBJECTIVE To measure the intrarater and interrater reliability of the visual assessment of cervical and lumbar lordosis. SUMMARY OF BACKGROUND DATA Cervical and lumbar lordoses are frequently evaluated using visual assessment, but little attempt has previously been made to measure the reliability of visual assessment. METHODS Twenty-eight chiroprac...

متن کامل

Interrater and Intrarater Reliability of the Tuck Jump Assessment by Health Professionals of Varied Educational Backgrounds.

Objective. The Tuck Jump Assessment (TJA), a clinical plyometric assessment, identifies 10 jumping and landing technique flaws. The study objective was to investigate TJA interrater and intrarater reliability with raters of different educational and clinical backgrounds. Methods. 40 participants were video recorded performing the TJA using published protocol and instructions. Five raters of var...

متن کامل

Intrarater and interrater reliability of 22 clinical measures associated with lower quarter malalignment.

OBJECTIVE The purpose of this study was to assess the intrarater and interrater reliability of a broad range of techniques commonly used to assess the lower quarter. METHODS A test-retest single group design was used to investigate the intrarater and interrater reliability of 22 lower quarter evaluation measures. Two raters conducted each measure twice on a total of 18 unimpaired subjects wit...

متن کامل

A comparison of large volume spacer, breath-activated and dry powder inhalers in older people.

AIMS To see if elderly people can use the breath-activated (Easi-breathe) and dry powder (Turbohaler) inhalers as effectively as the metered-dose inhaler and Volumatic system. METHODS 102 inhaler-naive patients (aged 75-101, mean 84 years), without cognitive impairment, were randomly allocated one of Easi-breathe, Turbohaler or metered-dose inhaler and Volumatic placebo inhalers. Standardized...

متن کامل

بررسی میزان کاربرد صحیح انواع اسپری استنشاقی توسط پزشکان ، داروسازان و پرستاران شاغل در بیمارستاهای آموزشی شهر همدان

Poor inhaler technique is a common problem both in asthma patients and health care providers , which contributes to poor asthma control. The aim of this study was to evaluate the correctness of metered-dose inhaler (MDI) technique in a sample of physicians , pharmacists and nurses practicing in Hamadan University hospitals. A total of 176 healthcare providers (35 internis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 105 3  شماره 

صفحات  -

تاریخ انتشار 1994