Effect of the phase volume ratio on the potential of a liquid-membrane ion-selective electrode.

نویسندگان

  • Zdenek Samec
  • Hubert H Girault
چکیده

Two-phase liquid system IA(w)|IX(o) comprising the interface between the aqueous solution (w) of uni-univalent electrolyte IA and an organic solvent solution (o) of a uni-univalent electrolyte IX with the common cation I(+) is considered as a simple model of a liquid-membrane ion-selective electrode (ISE). Taking into account the electroneutrality and mass balance conditions, the equilibrium Galvani potential difference (pd) between the aqueous and organic phases, phi = phi(w) - phi(o), is calculated numerically as a function of the ratio of the initial electrolyte concentrations, x = / = 10(-)(4)-10(4), for the selected values of the phase volume ratio r = V(o)/V(w) = 10(-)(3), 1, and 10(3), and the standard ion transfer potentials of the present ions ranging from -0.5 to 0.5 V. Numeric results corroborate the symbolic expressions derived for the cases when X(-) and A(-) are extremely lipophilic and hydrophilic ions, respectively, or when the concentration ratio x is extremely large or small. In contrast to the extraction system, where both electrolytes are initially present in the aqueous phase, the effect of the phase volume ratio on the equilibrium pd in the ISE model is rather weak, unless the counterions X(-) and A(-) differ little in their lipophilicity from the target ion I(+). It is shown that both the ISE and extraction model exhibit the Nernstian behavior only in a limited range of the concentration ratio x depending on the value of the standard ion transfer potentials of the counterions. When this ratio is extremely large or small, equilibrium pd approaches the limiting value given by the distribution potential of the electrolyte IA or IX, respectively. Similar conclusions can be drawn for the two-phase liquid system AI(w)|XI(o) with the common anion I(-).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid

Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...

متن کامل

Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion

A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Lanthanum(III) Ion Selective Electrode Based on a New Ionophore

A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

متن کامل

Cu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 76 14  شماره 

صفحات  -

تاریخ انتشار 2004