High-performance liquid chromatographic method for quantitative determination of amlodipine in human plasma and pharmaceutical dosage form and its application to pharmacokinetic studies.
نویسنده
چکیده
An accurate, sensitive, and reproducible high-performance liquid chromatographic method for the quantitation of amlodipine besylate in human plasma has been developed and validated. The drug, internal standard, and major metabolite were eluted from a C(18) hypersil HyPurity column (3 microm, 3.9 mm i.d. x 150 mm) at room temperature with a mobile phase consisting of acetonitrile-potassium dihydrogen phosphate buffer (0.05 M) and acetic acid (62:38:0.1) with the pH adjusted to 3.5 using phosphoric acid. The flow-rate was 1.8 mL/min. The limit of detection was 1.0 ng/mL, and the limit of quantification of amlodipine besylate in plasma was 10 ng/mL. The intra- and inter-day precisions showed coefficients of variation ranging from 5.98-11.4% and from 5.60-11.74%, respectively at three different levels of concentration. The averages of the absolute and relative recoveries were found to be 96.74-98.51% and 95.96-100.71%, respectively. Stability studies showed that amlodipine besylate is stable for at least 2 months in plasma after freezing at -20 degrees C. The method was successfully applied for a pharmacokinetic study and for the determination of commercial amlodipine tablet content.
منابع مشابه
High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies
A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...
متن کاملHigh-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies
A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatographic science
دوره 47 10 شماره
صفحات -
تاریخ انتشار 2009